Use and Care Manual

www.kegco.com 4 1-888-980-4810
Installation Instructions
BEFORE USE:
Remove the exterior and interior packaging, but do not remove any foam insulation surrounding the pipes at the
back.
Before connecting the unit to the power source, let it stand upright for approximately 8 hours. This will reduce
the possibility of a malfunction in the cooling system from handling during transportation.
Clean the interior surface with lukewarm water using a soft cloth.
Place the unit on a flat, solid floor that is strong enough to support it when it is fully loaded. To level the
appliance, adjust the rolling casters at the bottom of the unit.
When moving your refrigerator, please do not incline it more than 45 degrees.
Locate the appliance away from direct sunlight and sources of heat (stove, heater, radiator, etc.). Direct sunlight
may affect the acrylic coating and heat sources may increase electrical consumption.
The kegerator should be placed in an area where the ambient temperature is less than 100 degrees Fahrenheit
and higher than the lowest temperature you want to store your kegs at. If the ambient temperature is lower
than the set temperature, the internal temperature will match the ambient temperature.
Avoid locating the unit in damp areas.
Unwind the power cord to its full length and inspect for damage before plugging into the outlet.
Plug the refrigerator into an exclusive, properly installed and grounded wall outlet. Do not under any
circumstances cut or remove the third (ground) prong from the power cord. Any questions concerning power
and/or electrical grounding should be directed to a certified electrician or authorized products service center.
After plugging the appliance into a wall outlet, allow the unit to cool down for 3 to 4 hours before installing a
keg in the appliance.
Caster Installation
1. Remove everything from the cabinet and lay the unit on a clean, dry, and padded surface
2. Install casters into the holes on the bottom of the unit as shown and tighten with a wrench
3. The two casters equipped with locks should be installed on the front of the unit
4. Once all four casters are attached, return the beer dispenser to an upright position
5. Allow the unit to sit for 8-10 hours before plugging in to allow the refrigerant to settle
Guardrail Installation
1. Screw the guardrail lugs (1) into the top of the kegerator
2. Install the guardrail posts (2) on the guardrail lugs
3. Using the screws provided (3), fasten the guardrail posts onto the guardrail lugs