User Manual

Section 4: Command reference Series 2200 Programmable DC Power Supplies Reference Manual
4-38 2200S-901-01 Rev. A/November 2011
SYSTem:LOCal (no query form)
This command sets the power supply for control from the front-
panel.
Group
System
Syntax
SYSTem:LOCal
Related
Commands
SYSTem:LOCal (no query form) (on page 4-38)
SYSTem:RWLock (no query form) (on page 4-39)
Examples
SYS:LOC
SYSTem:POSetup
This command determines how the power supply initializes when
its power switch is turned on. This command configures the
instrument to power up with default settings, or power up with the
settings that were in effect when the instrument was turned off.
Group
System
Syntax
SYSTem:POSetup {RST|RCL0}
SYSTem:POSetup?
Arguments
RST: initializes the power supply to default settings after a power
cycle.
RCL0: saves the most recent settings and restores these after a
power cycle.
Returns
RST: default settings are applied after a power cycle.
RCL0: most recent settings are saved and restored after a power
cycle.
Examples
SYST:POS RST
SYSTEM:POSETUP? might respond with RST, which would indicate
that the power supply is configured to restore the power supply to
default settings when it powers up.