[SOURce:]VOLTage:PROTection:STATe
This command activates, deactivates, or checks the status of
overvoltage protection (OVP).
Group
Source
Syntax
[SOURce:]VOLTage:PROTection:STATe {0|1|OFF|ON}
[SOURce:]VOLTage:PROTection:STATe?
Related
Commands
[SOURce:]VOLTage:PROTection[:LEVel] (on page 4-26)
[SOURce:]VOLTage:RANGe (on page 4-28)
Arguments
0 or OFF sets the over voltage protection to off.
1 or ON sets the over voltage protection to on.
Returns
0|1 means the over voltage protection is off.
Examples
VOLT:PROT:STAT 1
VOLT:PROT:STAT? might return 1, which would indicate that