Installation Guide

15
T4BE-036KA SERIES
SUCT.
PRESS.
OUTDOOR TEMPERATURE (°F)
70 75 80 85 90 95 100 105
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
133 242 128
135
245 128
265 132
137 247 129
268 132
288 136
139
250 129
270 133
290 136
311 140
141 252 130
272 133
293 137
313 140
334 144
143 275 134
295 137
315 141
336 144
356 148
145 297 138
318 141
338 145
358 148
379 152
147 320 141
340 145
361 149
381 152
402 156
149 323 142 343 145
363 149
383 152
404 156
151 345 146 365 149
386 153
406 156
153 368 149 388 153
408 156
155 390 153 411 157
157 413 157
159
Table 8. Charging Table for 3 Ton Models
(Restrictor Matches)
T4BE-030KA SERIES
SUCT.
PRESS.
OUTDOOR TEMPERATURE (°F)
70 75 80 85 90 95 100 105
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
LIQ.
PRESS.
DIS.
TEMP.
135 242 131
137
243 132
265 135
139 244 132
266 135
287 138
141
245 132
266 135
288 138
310 141
143 246 132
267 135
289 138
310 141
332 144
145 268 135
290 138
311 141
333 144
354 148
147 290 138
312 141
334 144
355 147
377 151
149 313 141
335 144
356 147
378 151
399 154
151 314 141 335 144
357 147
379 150
400 154
153 336 144 358 147
379 150
401 153
155 359 147 380 150
402 153
157 381 150 403 153
159 404 153
161
Table 7. Charging Table for 2.5 Ton Models
(Restrictor Matches)
Shaded boxes indicate flooded conditions.
Rated design values. The suction pressure will vary from design value if indoor air flow, entering dry
bulb, or entering wet bulb temperatures are lower than design.
1. All pressures are listed in psig and all temperatures in ° F
2. Discharge temperatures greater than charted values indicate an undercharged system.
3. In Cooling Mode, suction pressure will be lower than design value if indoor air flow, entering dry bulb, or entering
wet bulb temperatures are lower than design.
4. In Heating Mode, charge should be weighed in. It is strongly recommended to verify charge in cooling mode
at ambient above 70°F.