Water Heater User Manual

Installation Instructions (cont'd)
A, WARNING
The appliance and its individualshutoffvalvemust:be discon-
nectedfromthe gassupplypipingsystemduringany pressure
testingof the gassystemat test pressuresin excessof
poundpersquareinch(3.5kPa).
The appliancemust be isolatedfromthegassupplypipingsys
tem by closingitsindividualmanualshutoffvalveduringany
pressuretestingof the gassupplypipingsystemat test pres-
suresequalorlessthan½ poundper square inch(3.5kPa).
li WARNING
Use pipe joint compound or teflon tape marked as being
resistant to the actionof petroleum[Propane(L.R)] gases.
GAS PIPING WITH
FLEXIBLE CONNECTOR
O,OO OO T
UNlON(Opti_ VE
CAP
SEDIMENT TRAP
A sediment trap shall be installed as close to the inlet of the
water heater as practical at the time of water heater installation.
The sediment trap shall be either a tee fitting with a capped nip-
ple in the bottom outlet or other device recognized as an effec-
tive sediment trap. If a tee fitting is used, it shall be installed in
conformance with one of the methods of installation shown
below.
Connecting the gas piping to the gas control valve of the water
heater can be accomplished by either of the two methods shown,
li WARNING
Contaminantsinthe gaslinesmaycauseimproperoperation
of the gascontrol valvethat may result in Ere or explosion.
Beforeattachingthe gaslinebe surethat allgaspipeisclean
on the inside.To trap any dirt or foreign material in the gas
supplyline, a drip leg (sometimes called a sediment trap)
must be incorporated in the piping. The drip leg must be
readily accessible.Installinaccordancewith the "Gas Piping"
section.Referto the latesteditionof the National Fuel Gas
Code,ANSI Z223.1, also referred to asNFPA 54.
GAS PIPING WITH ALL BLACK IRON
PIPE TO GAS CONTROL
GROUND JOINT _ BLACK PIPE
UNION(Optional) __
GAS
CONTROL
VALVE
15