Owners Manual FOR POTABLEWATER HEATING ONLY NOT SUITABLEFOR SPACEHEATING NOT FOR USE IN MOBILE HONES Model No. 153.332318 30 Gal. High Altitude 153.332362 30 Gal. 153.332418 40 Gal. High Altitude 153.332462 40 Gal. 153.332562 50 Gal.
Safety Precautions • AWARNING . . I Improper installation, adjustment, alteration, serveceor maintenance can cause DEATH, SERIOUS BODILY I INJURY, OR PROPERTY DAMAGE. Refer to this man.u- [ al for assistance or consult your local Sears Service I Center for further information. . I AWARNING WATER HEATERS EQUIPPED FOR ONE TYPE GAS ONLY: This water heater is equipped for one type gas only. Check the model rating plate near the gas control valve for the correct gas.
Safer-I iPrecautions AWARNING AWARNING A gas water heater cannot operate properly without the correct amount of air for combustion. Do not install in a confined area such a closet, unless you provide air as shownin the "Facts to Consider About the Location" section. Never obstruct the flow of vantilation air, If you have any doubts or questions at all, call your gas company.
Safety Precautions ._WARNIN, G _ I The water heater with draft hood InsteRedmust be prop- J erly vented to a chimney which terminates outdoors. JNever operate the water heater unlessit is ventedto the Joutdoors and h.asadequate air supply to avoid Msks of J . ] improper operation, explosionor asphyxiation. J AWARNING Minimum clearancesbetween the water heater and combustible or non-combustible construction are I" at the sides and rear, 4" at the front, and 6" from the vent pipe.
Table of Contents Safety Precautions ..................................................................................................... 2_ Table of Contents ............................................................................................................ .-. ................................ 5 Customer Re.s_onsibilities ....................................................................................... i..6 Product Specincations ...........................................................
Customer Responsibilities Thank You for • purchasinga Sears water heater. Properly installed and maintained, it should give you years of trouble free service. If you should.decide that you want the new water heater professionally installed by Sears call the local Sears Service Center or any Sears store. They will arrange _r prompt, quality installation by Sears authorized contractors. _ Abbreviations Found In This Instruction Manual A.G.A. - American Gas Association A.N.S.1.
Materials and Basic Tools Needed Materials Needed To simplify the installation Sews has available the installation parts shown below. You may or may not need all of these materials, depending on your type of installation.
Installation Instructions Removing the Old Water Heater Disconnect the vent pipe from the draft hood where they connect to the water heater. In most installations the vent pipe can be liked off after any screw or other attached devices are removed. Dispose of the draft. hood. The new water heater has the draft hood which must be used for proper operation. Turn "OFF _ the gas supply to the water heater. AWARNING If the main gas line shutoff serving all gas.
Installation Instructions (cont'd) Facts to Consider About the Location You should carefully choose an indoor location for the new water heater, because the placement is a very important consideration _or the safety of the occupants in the building and for the most economical use of the appliance. This water heater is not for use in mobile homes or outdoor installation. • The location selection must provide adequate clearances for servicing and proper operation of the water heater.
Installation Instructions (cont'd) Combustion Air and Ventilation for Appliances Located in Unconfined Spaces Unconfined Space is a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour of the aggregate input rating of all appliances installed in that space.
Installation Water Instructions (cont'd) Piping • AWARNING HOTTERWATER CAN SCALD:.Water heatersare intendedto Ptisfymduce hot water.Water _ to a temperaturewhichwill clotheswashing,dishwashing,and other sanitizingneeds canscaldand pemmnanffyinjureyou uponcontact.Somepeople aremore likelyto bepermanently injuredby hotwater than others.Theseincludetheelderly,children, theinfirm,or physically/meotallyhandicapped.
Installation Instructions (cont'd) Temperature-Pressure Relief Valve A, WARNING _,WARNING The temperature-preasure relief valve must be manually opereted at least once a year. CauCdon shouldbe teken to ensurethat (I) no one isin front of or aroundthe outlet of the temperature-pressure relief valvedischargeline, and (2) the water manually dischargedwill not causeany bodily injury or property damage because the water may be extremely hot.
Installation Filling the Water Instructions (cont'd) Heater .,CA ON I For proper venting in certain installations, a larger diameter vent pipe may be necessary. Due to great variances in installations, balforeseeable by the manufacturer of the water heater, you must consult your gas company to aid you in determining the proper venting for your water heater from the vent tables in the latest edition of the National Fuel Gas Code ANSI Z223.1, also referred to as NFPA 54.
Installation Instructions Venting (cont'd) Gas Piping All vent gases must be completely vented to the outdoors of the structure (dwelling). Install only the draft hood provided with the new water heater and no other drafthood. Vent pipes must be secured at each joint with sheet metal screws. __ -- "_ AWARNING Make sure the gas supplied is the same type listed on the model rating plate. The inlet gas pressure must not exceed 14 inches water column _A pound per square inch (3.5kPa).
Installation Instructions (cont'd) GAS PIPING WITH FLEXIBLE CONNECTOR AWARNING • The applianceand its individualshutoffvalvemustbe dlsconnetted flom the gassupplypipingsystemduringanypressure testing of the gas systemat test pressuresin excessof FLEKIBLEGAS CONNECTOR LABELED AS COMPLYING WITH ANSI STANDING • poundper squareinch(3.
Installation Installation Instructions Checklist BEFORE LIGHTING.THE PILOT: VENT PIPE TO OUTDOORS OR CHIMNEY • Check the gas lines for leaks. a. Use a soapy water solution. DO NOT test for gas leaks usinga match or open flame. b. Brush the soapy water solution on all gas pipes, joints and fittings. c. Check for bubbling soap. This means you have a leak. Turn OFF gas andmake the necessary repairs. d. Recheck for leaks. e. Rinse offsoapy solution and wipe dry.
Operating Instructions Lighting _,WARNING BEFORE LIGHTING [PROPANE (L.P.) GAS WATER HEATERS]:Propane(I.R) gasis heavierthan air.Shouldthere be a leak in the system,the gaswill settle near the ground. Basements,crawl spaces,skirted areas under mobile homes (eve. wi . vendL '), .. -ound lo/e[win serve as pockets for the accumulation of this gas. DeTore attemp_ngto lightor mlight the water heater'spilot or turning on a nearbyelectricallightswitch,be absolutelysurethere isno accumulatedgasin the area.
Operating Instructions Lighting label on the water FOR YOUR SAFETY heater (cont'd) as it appears READ above BEFORE the thermostat LIGHTING WARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or lose of life. This appliancehas a pilot whichmust be lightedby hand.Whenlightingthe pilot,followtheseinstructions exactly. B. BEFORELIGHTINGsmellall aroundthe appliancearea for gas.
Operating Temperature Instructions (cont'd) Regulation Turn the water temperature dial dockwise _f"_) to decrease the temperature, or counterclockwise (€"- _"_) to increase the temperature. Due to the nature of the typical gas water heater, the water tem_oerature in certain situations may vary up to 30°F higher or wer at the point of use such as, bathtubs, showers, sink, etc.
Service and Adjustment Tank (Sediment) Cleaning Burner Inspection Sediment build-up on the tank bottom may create varying amounts of noise, and if left in the tank will cause premature tank failure. In some water areas, you may not be able to drain all sediment deposits by simply draining the tank. In these cases Mag-Erad (part no. 23600) can be used to help remove the sediment deposits. This may be ordered from theSears Service Center. For ordering, refer to the Parts Order List section.
Service and Adjustment Drain Valve Washer Replacement Draining The water heater should be drained if being shut down during freezing temperatures. Also periodic draining and cleaning of sediment from the tank may be necessary. NOTE: For replacesurnt, use a '_" x _" x ¼" thick washer available at your nearest hardware stot_.. For ordering replacement washers, refer to the "Parts Order List" section. Turn the gas control knob to the _OFF _ position. CLOSE the cold water inlet valve to the water heater.
Troubleshooting Guide Start Up Conditions CONDENSATION THERMAL EXPANSION Whenever the water heater is filled with cold water, a certain amount of condensation will form while the burner is on: A water heater may appear to be leakingwhen in fact the water is condensation. This usually happens when: • When a new water heater is filled with cold water for the first time. • When gas burns and water vapor is produced in water heaters, particularly high efficiency models where flue temperatures are lower.
Troubleshooting Guide (cont'd) Operational HOT COLD SMELLY WATER WAT_ HEATER COLDWATER bINLETFITTING PRESSURE REDUCING VALVEWITH BY-PASS In each glasslined water heater there is installed at least one anode rod (see parts section) for corrosion protection of the tank. Certain water conditions will cause a reaction between this rod and the water. The most common complaint associated with the anode rod is one of a "rotten egg smell".
Troubleshooting Operational (cont'd) HIGH Guide (cont'd) Conditions TEMPERATURE SHUT OFF SYSTEM WATER This water heater is equipped with an automatic gas shut offsystern. The high temperature shut off is built into the gas control valve. This system shuts off the gas supply to the water heater burners when high water temperatures are present. It is nonresettable. If the high temperature shut off activates, the gas control valve must be replaced.
Troubleshooting Guide (cont'd) Leakage Checkpoints Use this guide to check a "Leaking_ water heater. Many suspected "Leakers_ are not leaking tanks. Often the source of the water can be found and corrected. A CAUTION Read this mhnual first. Then before checking the water heater make sure the gas supply has been turned "OFF", and "neverturn the gas "ON" before the tank is I completely full of water.
Parts Order THE ECONOMIZER MODEL NUMBERS: 153.332318 153.332362 153.332418 153.332462 153.332562 30 30 40 40 50 TM List 5 GAS WATER HEATERS G'al. High Altitude Gal. Gal. High Altitude Gal. Gal. m 16 O.
Parts Order THE ECONOMIZER MODEL NUMBERS: 153.332318 153.332362 153.332418 153.332462 153.332562 30 30 40 40 50 TM List (cont'd) 5 GAS WATER HEATERS Gal. High Aldtude Gal. _al. High Altitude Gal. Gal. Model Numbers KEY NO. 153.332318 ] 153.
Warranty a. Adjustingthermostat b. Lightingpilot c.Leaksin pipes or fittings d. Improperventing e. Condensation About Your Warranty THE PRICEOF YOUR WATER HEATER DOES NOT INCLUDE A FREE CHECKUP SERVICE CALL. On Water Heater Installations Arranged BySears,Searswirrants the installation. ON INSTALLATIONS NOT MADE BY SEARS AUTHORIZED CONTRACTORS: 1.YourSearswarranty appliesto the product only. 2. Searsdoes not warrant the installation. 3.