Once the unit is plugged in, the POWER INDICA-
TOR (10) will light. Pressing the POWER button
once will turn the unit ON and illuminate the digi-
tal display (9). The fan will operate for 3 minutes
to draw air through the dehumidifier to properly
sense relative humidity. The display will show the
humidity level of the room in 5% increments,
down to a minimum of 25%. Pressing the Power
button again will turn the display OFF and the
unit will cease operating.
HUMIDITY LEVEL(2/3)
The humidity level can be set in 5% incrementsin
a range from 35% to 80%. The humidity setting
isshownin the digital display. When the humidi-
ty level of the room reaches the set level, the
compressor will stop, but the fan will continue
operating for 3 minutes.To set the unit to continu-
ousoperation, pressthe clownarrow button until
the display shows35%. Pressagain and the dis-
play will showCO. The Continuousindicator (13)
will light up on the control panel. To leave contin-
uousoperation, pressthe UParrow.
To check the current humiditysetting, pressthe up
or down arrow. The display will showand set 5%
above or below the currentsettings.
FAN SPEED(5)
PressFan Speed to toggle between Low,Med,
and Highfan speeds. Speed will be shownin FAN
SPEEDINDICATOR (8)
BUCKETFULLINDICATOR (11)
When the collection bucket isfull, the BUCKET
FULLIndicator (11)will light up and you will hear
an audible alarm. The audible alarm will lastup
to ten secondsThe dehumidifier will not rununtil
the bucket is removed, emptied and replaced.
(3) (1) (6)
DELAY START (4)
Unit can be programmed to turn on at a desired
delay time by pressing the Timer (4) key. When
the unit is powered OFF, press the timer key once
for 2-hour delay start. The 2 Hrs (7) timer indica-
tor will light up when the timer key is pressed.
Pressthe timer key once more for a 4-hour delay
start. The 4 Hrs (7) timer indicator will now light
up. Pressthe timer key a third time to clear the
timer setting. No timer indicators will light up
when the timer setting is cleared.
AUTO SHUT-OFF (4)
Unit can be programmed to turn off at a desired
time by pressing the Timer (4) key. When the unit
is powered ON, press the timer key once for 2-
hour automatic shut-off. The 2 Hrs (7) timer indi-
cator will light up when the timer key is pressed.
Pressthe timer key once more for a 4-hour auto-
matic shut-o_. The 4 Hrs (7) timer indicator will
now light up. Press the timer key a third time to
clear the timer setting. No timer indicators Will
light up when the timer setting is cleared.
FILTERRESET(12)
The FILTERRESETindicator (12) will light up when
the filter needscleaning. Removethe filter and
clean accordingly. Replace the filter when fin-
ishedand pressand hold the FILTER(6) key upto
5 secondsto resetthe filter indicator.
IMPORTANT.
Once the set humidity level isreached, the
compressorwill shutoff. The fan will contin-
ueto runfor up to 3 minutes.
Anytime the compressorstopsrunning for
any reason, it will not restart for a minimum
of 3 minutes.Thisis a design feature to pro-
tect the compressorfrom damage.