Max Connected Required Power Minimum
Kenyon Part # Model # Load Supply Input Wire Size
B41540 Med2QTCP 2600 Watts 120V AC/22A/50/60Hz #12 AWG
B41549 Med2QTCP 3000 Watts 208V AC/14.5A/50/60Hz #12 AWG
B41541 Med2QTCP 3000 Watts 240V AC/12.5A/50/60Hz #12 AWG
B41540L Med2QTCL 2600 Watts 120V AC/22A/50/60Hz #12 AWG
B41549L Med2QTCL 3000 Watts 208V AC/14.5A/50/60Hz #12 AWG
B41541L Med2QTCL 3000 Watts 240V AC/12.5A/50/60Hz #12 AWG
B41575 & B41775 Med2QTCTP 2400 Watts 120V AC/20A/50/60Hz #12 AWG
B41775T30 Med2QTCTP 2400 Watts 120V AC/20A/50/60Hz #12 AWG
B41579 & B41779 Med2QTCTP 2400 Watts 208V AC/11.5A/50/60Hz #12AWG
B41579T30 & B41779T30 Med2QTCTP 2400 Watts 208V AC/11.5A/50/60Hz #12AWG
B41576 & B41776 Med2QTCTP 2400 Watts 240V AC/10A/50/60Hz #12 AWG
B41576T30 & B41776T30 Med2QTCTP 2400 Watts 240V AC/10A/50/60Hz #12 AWG
B41575L & B41775L Med2QTCTL 2400 Watts 120V AC/20A/50/60Hz #12 AWG
B41575LUST30 Med2QTCTL 2400 Watts 120V AC/20A/50/60Hz #12 AWG
B41775LT30 Med2QTCTL 2400 Watts 120V AC/20A/50/60Hz #12 AWG
B41579L & B41779L Med2QTCTL 2400 Watts 208V AC/11.5A/50/60Hz #12 AWG
B41579LT30 & B41779LT30 Med2QTCTL 2400 Watts 208V AC/11.5A/50/60Hz #12 AWG
B41576L & B41776L Med2QTCTL 2400 Watts 240V AC/10A/50/60Hz #12 AWG
B41576LT30 & B41776LT30 Med2QTCTL 2400 Watts 240V AC/10A/50/60Hz #12 AWG
B41796 & B41796T30 Glacier2TC 2600 Watts 120V AC/22A/50/60Hz #12AWG
B41798 & B41798T30 Glacier2TC 3000 Watts 208V AC/14.5A/50/60Hz #12AWG
B41797 & B41797T30 Glacier2TC 3000 Watts 240V AC/12.5A/50/60Hz #12AWG
STEP #2
Check the Electrical Supply Requirements
This product must be installed in accordance with national, state and local electric codes. The
following table provides the correct voltage, amperage and frequency that must be supplied to the
cooktop.
The supply must be from an individual grounded circuit that is protected by a circuit breaker and
rated per the speciîš¿cations for the various models as shown in the table above.