2-1 Installation and Connection to Sensor Amplifiers
2-6
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (GT-70A) -
2
Connection and Configuration
Connecting to sensor amplifiers (panel mounting type)
1
Connect the optional expansion cable (OP-35361) between the sensor
amplifier and the DeviceNet compatible communication unit, DL-DN1.
2
Remove the sensor amplifier connector (for DIN rail mounting type) from
the DeviceNet compatible communication unit, DL-DN1, using pliers. In its
place, attach the expansion connector sticker supplied with the DL-DN1.
Turn off the power and connect the expansion cable securely. If
the cable is not correctly connected, the DL-DN1 may be
damaged when the power is turned on.
Do not attach or detach the cable with the power on, as this may
damage the DL-DN1.
Peel off the protective sticker.
Expansion cable (300 mm long)
NOTICE
Sensor amplifier connector
(for DIN rail mounting type)
Expansion connector sticker