User Manual

3-2 I/O Communication
3-8
- DeviceNet Compatible Network Unit DL-DN1 Userโ€™s Manual (GT-70A) -
3
Communicating with the GT-70A series
๎‚„ Error information list
Error ID
number
(HEX)
Error
code
(HEX)
Description Cause Corrective action
00h
01h Initialization error Error encountered during
initialization.
Check the number of
connected sensor amplifiers
and the connection to the
sensor amplifiers, and then
cycle power. If the error
remains, contact your nearest
sales office.
04h Mixed connection error A foreign sensor amplifier (i.e.,
one that is not compatible) is
connected.
Remove the foreign sensor
amplifier.
06h Number-of-units error More sensor amplifiers are
connected than are permitted.
Check the number of
connected sensor amplifiers.
nnh
(01h - 0Fh)
01h Error 1 for sensor amplifier
of ID number nn
Overcurrent error (ErC)
Refer to the GT-70A series
user's manual.
02h Error 2 for sensor amplifier
of ID number nn
Head error (ErH)
03h Error 3 for sensor amplifier
of ID number nn
EEPROM error (ErE)
04h Error 4 for sensor amplifier
of ID number nn
Jam check error (Er.chK)
05h Error 5 for sensor amplifier
of ID number nn
Self-timing delay error (Er.dLY)
06h Error 6 for sensor amplifier
of ID number nn
Number-of-units error (Er.Unit)
07h Error 7 for sensor amplifier
of ID number nn
Calculation error (Er.CAL)
1Dh
02h/
04-07h
System error An error occurred in the
internal system.
Check the connection to the
sensor, and then cycle power.
If the error can not be
corrected, contact your
nearest sales office.
03h Model error There is a sensor amplifier
connected that is incompatible
with the DL-DN1.
Connect a sensor amplifier of
a compatible model.
1Fh - No error - -