User Manual

3-2 I/O Communication
3-13
3
Communicating with the GT-70A series
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (GT-70A) -
5-output mode
OUT area
m: The first device number assigned to the DL-DN1
IN area
n: The first device number assigned to the DL-DN1
The device assignments are the same for all 5-output modes including extended
modes.
Rewrite setting value
Sensor amplifier ID numbers 01 to 10 are assigned to bits 0 to 9, respectively.
For details of communication methods, see "Rewriting a Setting Va lue of a Sensor
Amplifier" (page 3-19).
3-output mode
OUT area
m: The first device number assigned to the DL-DN1
Device
(DEC)
Name
Bit 7 Bit 6 ··· Bit 1 Bit 0
Bit 15 Bit 14 ··· Bit 9 Bit 8
m+5 Request to change bank
ID08 ID07 ··· ID02 ID01
Reserved ID15 ··· ID10 ID09
m+6 Select bank number
Specifi es a new bank number
(2-byte unsigned integer).
Device
(DEC)
Name
Bit 7 Bit 6 ··· Bit 1 Bit 0
Bit 15 Bit 14 ··· Bit 9 Bit 8
n+11 Bank change complete
ID08 ID07 ··· ID02 ID01
Reserved ID15 ··· ID10 ID09
n+12 Bank change error
ID08 ID07 ··· ID02 ID01
Reserved ID15 ··· ID10 ID09
Device
(DEC)
Name
Bit 7 Bit 6 ... Bit 1 Bit 0
Bit 15 Bit 14 ... Bit 9 Bit 8
m+3
Request to rewrite HIGH
(bank 0) setting
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
m+4 to 5
HIGH
(bank 0)
setting
HIGH
(bank 0) setting to be rewritten
(4-byte signed integer)
m+6
Request to rewrite LOW
(bank 0) setting
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
m+7 to 8
LOW
(bank 0)
setting
LOW
(bank 0) setting to be rewritten
(4-byte signed integer)
m+9
Request to rewrite
PRESET (bank 0)
setting
ID08 ID07 ... ID02 ID01
Reserved ID15 ... ID10 ID09
m+10 to 11 PRESET (bank 0)
setting
PRESET (bank 0) setting to be rewritten
(4-byte signed integer)