User Manual

3-3 Explicit Messaging
3-30
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (GT-70A) -
3
Communicating with the GT-70A series
Nx10+4
68
Response time
R/W 3
0: HSP (1.5)
1: 5 ms
2: 10 ms
3: 100 ms
4: 500 ms
5: 1000 ms
6: 5000 ms
69
Timing type
R/W 0
0: External timing input
1: Rising self
2: Falling self
6A
Self timing level
R/W +000.500
-099.999 to +999.999
6B
Self-timing delay type
R/W 0
0: Static hold
1: Delay timer
6C
User-specified delay time
R/W 1000
0 to 9999
6D
Static hold delay stable determination
R/W 0
0: Default
1: User
6E
Static hold delay stab le range
R/W +000.010
+000.000 to +999.999
6F
Measurement increase/decrease
direction
R/W 0
0: Normal
1: Reverse
70
Multiplier
R/W 001.0
000.1 to 100.0
71
Output mode
R/W 0
0: N.O.
1: N.C.
72
Display resolution
R/W 0
0: 0.0001
1: 0.001
2: 0.01
3: 0.1
73
Hysteresis
R/W +000.003
+000.000 to +999.999
74
Input (purple wire) function selection
1
R/W 0
0: Bank A
1: Reset
75
Input (pink/purple wire) function
selection 2
R/W 0
0: Timing input
1: Bank B
76 to
78
System reserved
79
Preset memory
R/W 0
0: YES
1: NO
7A
System reserved
7B
Power-saving function (ECO)
R/W 0
0: OFF
1: HALF
2: ALL
7C
Jam detection function
R/W 0
0: OFF
1: ON
2: USER
7D
Check point setting
R/W +000.500
-99.999 to +999.999
7E
Display filter function
R/W 0
0: ON
1: OFF
7F to
83
System reserved
Nx10+5
64
Group-5 entry count
R10
65
R.V. value of main unit (ID: 01) on
which calculation result was based
*3
*10
R
66
R.V. value of expansion unit (ID: 02)
on which calculation result was
based
*3
*10
R
67
R.V. value of expansion unit (ID: 03)
on which calculation result was
based
*3
*10
R
InstID
(DEC)
AttrID
(HEX)
Name
Description
Attribute
Default
value
Parameter range