52” Lucian™LED 2 * 2 * Includes our new Wall Remote Control System Kichler® Lighting 7711 East Pleasant Valley Road P.O. Box 318010 Cleveland, Ohio 44131-8010 Customer Service 866.558.
1 1. SAFETY RULES 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning. 9. To avoid personal injury or damage to the fan and other items, be cautious when working around or cleaning the fan. 2. All wiring must be in accordance with the National Electrical Code and local electrical codes. Electrical installation should be performed by a qualified licensed electrician. 10.
TM 52" Lucian LED 2 2. TOOLS AND MATERIALS REQUIRED Philips screw driver Blade screw driver 11 mm wrench Step ladder Wire cutters 3. PACKAGE CONTENTS a. b. c. d. e. f. Fan blades (5) Canopy & Ceiling mounting bracket Ball/downrod assembly Coupling cover Fan motor assembly Set of 5 blade brackets and Pre-Installed mounting screws g. Light plate h. 16W LED light kit i. Glass shade j. Decorative bottom cover k. Receiver l. Wall Transmitter m.
3 4. MOUNTING OPTIONS If there isn't an existing UL (cUL for Canadian Installation) listed mounting box, then read the following instructions. Disconnect the power by removing fuses or turning off circuit breakers. Outlet box Fig. 1 Secure the outlet box directly to the building structure. Use appropriate fasteners and building materials. The outlet box and its support must be able to fully support the moving weight of the fan (at least 50 lbs). Do not use plastic outlet boxes.
TM 52" Lucian LED 5. HANGING THE FAN Hanger bracket REMEMBER to turn off the power before you begin. Ceiling canopy To properly install your ceiling fan, follow the steps below. Canopy cover Step 1. Remove the decorative canopy bottom cover from the canopy by turning the cover counter clockwise. (Fig. 5) Step 2. Remove the ceiling mounting bracket from the canopy by removing (and save one of the two screws. Loosen the remaining screw by a half turn. (Fig. 5) Fig.
5 Step 8. Slip the coupling cover, canopy cover and canopy onto the downrod. Thread the hanger ball onto the downrod, insert the cross pin through the downrod and tighten. Now tighten the set screw. (Fig. 9) Downrod Canopy Step 9. Lift the motor assembly into position and place the hanger ball into the ceiling mounting bracket. Canopy cover Coupling cover Set screws Hitch pin Retaining clip Fig. 9 Registration slot Fig.
TM 52" Lucian LED 6. INSTALLATION OF SAFETY SUPPORT (required for Canadian installation ONLY) A safety support cable is provided to help prevent the ceiling fan from falling, please install it as follows. Step 1. Attach the provided wood screw and washers to the ceiling joist next to the mounting bracket but do not tighten. (Fig. 11) Step 2.
7 Outlet box White (neutral) Black (hot) Green or bare copper (ground) White ("AC IN N") Black ("AC IN L") Receiver Black ("to motor L") White ("to motor N") Blue (for light) Ground (green) Blue (for light) Black (motor) (Connect to ground wire on hanger bracket if no house ground wire exists.) White (neutral) Connect the white wire from the fan to the white wire marked "TO MOTOR N" on the receiver. Connect the blue wire from the fan to the blue wire marked "FOR LIGHT" on the receiver.
TM 52" Lucian LED 9. ATTACHING THE FAN BLADES CAUTION: Remove the rubber shipping plate attached to the face of the motor. These plate keep the motor from shifting during shipping and MUST be removed during installation. Step 1. Attach a blade to a blade bracket using the screws and fiber washers provided. (Fig. 16) Screws Make sure the blade is straight when set on the blade bracket. Tighten each mounting screw and then repeat this procedure for each blade.
9 11. INSTALLING THE LED LIGHT KIT AND GLASS SHADE NOTE: Before starting installation, disconnect the power by turning off the circuit breaker or removing the fuse at fuse box. Light plate Wire connectors LED light kit Screws Fig. 18 Step 1. Loosen the three mounting screws on the inside of the LED light kit. (Fig.18) Step 2. While holding the LED light kit under the fan motor, make the wire connections: (Fig.
TM 52" Lucian LED 12. INSTALLING THE BATTERIES Remove the face plate of the Wall Switch by lifting at the top and then insert the supplied 12V battery. Duracell MN21/Eveready A23/GP 23A all 12V. U/L HI LIGHT MED D/L LOW Replace the switch face plate. ON ECE FAN OFF 1 2 3 4 23AE 12V To prevent possible damage to the transmitter, remove these batteries if not used for long periods of time (months). Fig. 21 13.
11 14. INSTALLING THE BASIC FUNCTION WALL CONTROL SYSTEM WALL PLATE Outlet box Switch Wall plate Select a location to install the Basic Function Wall Control System Transmitter and Wall Plate. Install the wall plate using an existing wall switch outlet box. Make sure the electrical power is TURNED OFF at the main panel before continuing. Fig. 24 Step 1. Remove the existing wall plate and the old switch from the wall outlet box.
TM 52" Lucian LED 15. OPERATING INSTRUCTIONS The Black Slide Switch on the side of the switch housing controls the direction of the blades "Forward and Reverse". Warm weather - Forward (counter clockwise) A downward airflow creates a cooling effect as shown in Fig. 26. This allows you to set your air conditioner on a warmer setting without affecting your comfort. Cool weather - Reverse (clockwise) An upward airflow moves warm air off the ceiling area as shown in Fig. 27.
13 16. TROUBLESHOOTING Problem Solution Fan will not start. 1. Check circuit fuses or breakers. 2. Check all electrical connections to insure proper contact. CAUTION: Make sure the main power is OFF when checking any electrical connection. 3. Make sure the transmitter batteries are installed properly. Positive (+) side facing out. 4. Insure the batteries have a good charge. Fan sounds noisy. 1. Make sure all motor housing screws are snug. 2.