1) Run the wire through the O-Ring[H] and through the top
loop[G] to install onto the main body. Install the other O-Ring
and top loop to the other side.
2) Aach both chains[F] to the top loops[G] of main body[I].
Aach chain to the loops[M] on the canopy[E]. Close the
loops.
3) Weave electrical wire and ground wire through chain links no
more than 3 inches apart. Pass wire through the canopy.
4) Find the appropriate threaded holes on mounng strap[A].
Assemble mounng screws[B] into threaded holes.
5) Aach mounng strap[A] to outlet box[D] using the strap
mounng screws[C]. The mounng strap can be adjusted to
suit posion of xture.
6) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a hole
and two raised dimples, wrap ground wire from outlet box
around green ground screw, and thread into hole.
b) On xtures where a cupped washer is provided, aach
ground wire from outlet box under cupped washer and
green ground screw, and thread into mounng strap.
If xture is provided with ground wire, connect xture ground
wire to outlet box ground wire with wire connector aer
following the above steps. Never connect ground wire to black
or white power supply wires.
7) Make wire connecon. Reference chart below for correct
connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply Wire
to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or Black
without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other than
green) with silver conductor
*Note: When parallel wire (SPT 1 &
SPT 2) are used. The neutral wire
is square shaped or ridged and the
other wire will be round in shape or
smooth (See illus.)
Neutral Wire
8) Aach the inspecon cable[L] to the mounng strap or to the
inside of the mounng box. Push xture to ceiling, carefully
passing mounng screws through holes in canopy. NOTE: Be
certain wires do not get pinched between ceiling and canopy.
9) Use the two (2) lockup knobs[K] and two (2) lockwashers[J]
to secure canopy. Tighten to secure.
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
Fixture Diagram
Parts List
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance
with the Naonal Electrical Code (NEC) and all local code
specicaons. If you are not familiar with code requirements,
installaon by a cered electrician is recommended.
Installaon Instrucons
Installaon Instrucons (connued)
[A] Mounting
Strap
[B] Mounting
Screw
[C] Strap
Mounting
Screw
[D] Outlet Box
[E] Canopy
[F] Chain
[G] Top Loop
[H] O-Ring
[I] Main Body
[J] Lockwasher
[K] Lockup Knobs
[L] Inspection
Cable
[M] Loops
E
B
A
D
K
M
J
F
G
H
I
C
L