20) Make wire connections (connectors not provided). Reference
chart below for correct connections and wire accordingly.
21) Raise canopy to ceiling.
22) Secure canopy in place by tightening threaded ring onto
screw collar loop.
23) Slip candle covers over sockets.
24) Lower one glass panel down behind bar on fixture.
25) Align hole in glass panel with hole in bar. Thread finial into
hole in glass panel and into hole in bar. Carefully tighten
finial to secure glass in place. (DO NOT over tighten.)
To assemble lower ring to upper ring:
1) Slip end of one open chain link on to loop on lower ring of
fixture body.
2) Slip other end of open chain link over loop on bottom of one
short arm. Close chain link.
3) Slip end of one open chain link over loop on top of short arm
from steps 1 and 2.
4) Slip other end of open chain link over loop on bottom of
upper ring. Close chain link.
5) Repeat steps 1 through 4 for remaining short arms.
To assemble upper ring to canopy:
6) Slip end of one open chain link on to loop on upper ring of
fixture body.
7) Slip other end of open chain link over loop on bottom of one
long arm. Close chain link.
8) Slip end of one open chain link over loop on top of long arm
from steps 6 and 7.
9) Slip other end of open chain link over loop on canopy. Close
chain link.
10) Repeat steps 6 through 9 for remaining long arms.
11) TURN OFF POWER.
IMPORTANT: Before you start, NEVER attempt any work
without shutting off the electricity until the work is done.
a) Go to the main fuse, or circuit breaker, box in your
home. Place the main power switch in the “OFF”
position.
b) Unscrew the fuse(s), or switch “OFF” the circuit breaker
switch(s), that control the power to the fixture or room
that you are working on.
c) Place the wall switch in the “OFF” position. If the fixture
to be replaced has a switch or pull chain, place those in
the “OFF” position.
12) Take threaded pipe from parts bag and screw in screw collar
loop a minimum of 6 mm (1/4”). Lock into place with hexnut.
13) Run another hexnut down threaded pipe almost touching
first hexnut. Now screw threaded pipe into mounting strap.
Mounting strap must be positioned with extruded thread
faced into outlet box. Threaded pipe must protrude out the
back of mounting strap. Screw third hexnut onto end of
threaded pipe protruding from back of mounting strap.
14) Connect mounting strap to outlet box.
15) Unscrew the threaded ring from screw collar loop. Take
canopy and pass over screw collar loop. Approximately one
half of the screw collar loop exterior threads should be
exposed. Adjust screw collar loop by turning assembly up or
down in mounting strap. Remove canopy.
16) After desired position is found, tighten both top and bottom
hexnuts up against the bottom and top of the mounting
strap.
17) Slip canopy over screw collar loop and thread on threaded
ring. Attach chain (with fixture connected) to bottom of
screw collar loop. Unscrew threaded ring, let canopy and
threaded ring slip down.
18) Weave electrical wire and ground wire through chain links no
more than 3 inches apart. Pass wire through threaded ring,
canopy, screw collar loop, threaded pipe and into outlet box.
19) Grounding instructions: (See Illus. A or B).
A) On fixtures where mounting strap is provided with a
hole and two raised dimples. Wrap ground wire from
outlet box around green ground screw, and thread into
hole.
B) On fixtures where a cupped washer is provided. Attach
ground wire from outlet box under cupped washer and
green ground screw, and thread into mounting strap.
If fixture is provided with ground wire. Connect fixture
ground wire to outlet box ground wire with wire connector
(not provided.) after following the above steps. Never
connect ground wire to black or white power supply wires.
GREEN GROUND
SCREW
CUPPED
WASHER
A
B
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
(NOT PROVIDED)
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth) *Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire
Date Issued: 4/24/15 IS-43704-US
SEE OTHER SIDE FOR SPANISH TRANSLATIONS.
VEA EL OTRO LADO DE TRADUCCIONES AL ESPAÑOL.
Were here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
MOUNTING STRAP
PLANCHA PARA MONTAR
LOOP
LAZO
HEXNUT
TUERCA HEXAGONAL
THREADED PIPE
TUBO ROSCADO
THREADED RING
ANILLO ROSCADO
SCREW COLLAR LOOP
OJAL DE COLLAR
ROSCADO
CANOPY
ESCUDETE
LONG ARM
BRAZO LARGO
LOOP
LAZO
GLASS PANEL
PANEL DE VIDRIO
CHAIN LINK
ESLABÓN DE
LA CADENA
CHAIN LINK
ESLABÓN DE
LA CADENA
CANDLE COVER
CUBIERTA DE LA
VELA
LOWER RING
ANILLO INFERIOR
FINIAL
CAPUCHÓN
SHORT ARM
BRAZO CORTO
UPPER
RING
ANILLO
SUPERIOR

Summary of content (2 pages)