Warranty

standards for the specified occupancy, approved single- and multi-
ple-station smoke alarms shall be installed as follows: (1) In all
sleeping rooms Exception: Smoke alarms shall not be required in
sleeping rooms in existing one- and two-family dwelling units. (2)
Outside of each separate sleeping area, in immediate vicinity of
the sleeping rooms. (3) On each level of the dwelling unit, includ-
ing basements Exception: In existing one- and two-family dwelling
units, approved smoke alarms powered by batteries are permitted.
Smoke Detection - Are More Smoke Alarms Desirable? The
required number of smoke alarms might not provide reliable early
warning protection for those areas separated by a door from the
areas protected by the required smoke alarms. For this reason, it is
recommended that the householder consider the use of additional
smoke alarms for those areas for increased protection. The addi-
tional areas include the basement, bedrooms, dining room, fur-
nace room, utility room, and hallways not protected by the
required smoke alarms. The installation of the smoke alarms in
the kitchen, attic (finished or unfinished), or garage is normally not
recommended, as these locations occasionally experience condi-
tions that can result in improper operation.
This equipment should be installed in accordance with the
National Fire Protection Association’s Standard 72 (NFPA,
Batterymarch Park, Quincy, MA 02269).
NOTIFY YOUR LOCAL FIRE DEPARTMENT AND INSURANCE COM-
PANY OF YOUR SMOKE ALARM INSTALLATION.
10. CAUTION (AS REQUIRED BY THE CALIFORNIA
STATE FIRE MARSHAL)
“Early warning fire detection is best achieved by the installation of
fire detection equipment in all rooms and areas of the household
as follows. A smoke alarm installed in each separate sleeping area
(in the vicinity of, but outside of the bedrooms), and heat or
smoke alarms in the living rooms, dining rooms, bedrooms,
kitchens, hallways, attics, furnace rooms, closets, utility and stor-
age rooms, basements and attached garages”.
11. SERVICE AND WARRANTY
If after reviewing this manual you feel that your smoke alarm is
defective in any way, do not tamper with the unit. Return it for
servicing to: KIDDE Safety, 1016 Corporate Park Dr., Mebane, NC
27302. 1-800-880-6788 (See Warranty for in-warranty returns).