LED INDICATORS: This smoke alarm is equipped with red and
green LED indicators. The red LED is located under the test button
and has two modes of operation.
Standby Condition: The red LED will flash every 30-40 seconds
to indicate that the smoke alarm is
operating properly.
Alarm Condition: When the alarm senses products of
combustion and goes into alarm, the red
LED will flash rapidly (one flash per second).
The rapid flashing LED and pulsating alarm
will continue until the air is cleared.
SMOKE SENSING CHAMBER OPERATION: This alarm will “chirp” if
any of the components in the smoke sensing chamber fail. This
chirp will occur between the flashes of the red LED indicator light.
(If the chirp occurs at the same time as the red LED flash, see sec-
tion 6 for low battery information).
WHEN UNITS ARE INTERCONNECTED, only the red LED of the
alarm which senses the smoke or is being tested (the originating
unit) will flash rapidly. All other units in the interconnect system
will sound an alarm but their red LED’s will NOT flash rapidly.
The green LED will be steady on to indicate the presence of AC
power.
TESTING: Test by pushing the test button on the cover and holding
it down for a minimum of 5 seconds. This will sound the alarm if
the electronic circuitry, horn, and battery are working. In an inter-
connected installation all interconnected alarms should sound
when the test button on any one of the interconnected alarm is
pressed. If no alarm sounds, check the fuse or circuit breaker sup-
plying power to the alarm circuit. If the alarm still does not sound,
the unit has defective batteries or other failure. DO NOT use an
open flame to test your alarm, you could damage the alarm or
ignite combustible materials and start a structure fire.
TEST THE ALARM WEEKLY TO ENSURE PROPER OPERATION. Erratic
or low sound coming from your alarm may indicate a defective
alarm, and it should be returned for service (see section 12).
NOTE: WEEKLY TESTING IS REQUIRED.
5. NUISANCE ALARMS
Smoke alarms are designed to minimize nuisance alarms.