Instructions / Assembly

2
INSTALLATION INSTRUCTIONS
SAVE THESE INSTRUCTIONS
DANGER
!
!
ELECTRIC SHOCK OR FIRE HAZARD
READ ALL WIRE SIZING, VOLTAGE REQUIREMENTS AND
SAFETY DATA TO AVOID PROPERTY DAMAGE AND
KING ELECTRIC MFG CO · 9131 10TH AVENUE SOUTH · SEATTLE, WA 98108 · PH:206 762 0400 · FAX: 206 763 7738 · www.king-electric.com
TKIT-1 &
TKIT-2
Approved for
US & Canada
SPECIFICATIONS Resistive Load
Source 120 VAC 25 AMP @ 3000W
Source 208 VAC 25 AMP @ 5200W
Source 220 VAC 25 AMP @ 5500W
Source 240 VAC 25 AMP @ 6000W
Source 277 VAC 18 AMP @ 4985W
Temperature range 40°-90°F (4°-32°C)
Frequency 50-60 Hz
Accuracy 7°F +/- 3.5°C
Inductive Load 1/2HP
Fig 1
Rev 9.19.18
Inbuilt Thermostat for the PX, KT,
KTW, PAW, W and WHF model heat-
ers
PAW Models
KT & KTW Models W Models
WHF Models
MOUNTING LOCATIONS
Use the two sheet metal screws provided to fasten the mounting bracket as shown above. Use the two machine
screws to mount the thermostat to the mounting bracket.
PX Models