Installation Guide

First Revision July 2016
Insulation
INSTALLATION GUIDELINES
XPS Insulation Board
Product
Kingspan GreenGuard
®
XPS Insulation Board comprises closed–
cell extruded polystyrene (XPS) with high water resistance and R–
value of 5.0 per inch of thickness. It is available as Type IV in square
edge board, ship–lap edge board and a score board and Type VI in
square edge or drainage channels.
1. Kingspan GreenGuard
®
XPS Insulation Board CM
(square edges 1/2 – 3 in., Type IV and 2-3 in., Type VI);
2. Kingspan GreenGuard
®
XPS Insulation Board SB
(scored board: 1-2 in., Type IV);
3. Kingspan GreenGuard
®
XPS Insulation Board DC
(drainage channels, 2 in., Type VI);
4. Kingspan GreenGuard
®
XPS Insulation Board SL
(shiplap edges, ½ - 2 in., Type IV); and
5. Kingspan GreenGuard
®
SLX Sheathing (lm-faced,
shiplap edges, ½ - 1 in., Type IV);
Compliance
The installer is responsible for ensuring that the installation is
in compliance with building code requirements. The code may
have requirements for specic insulation thickness or R-value and
materials along with specic thermal or ignition barriers.
All assemblies should be evaluated for effectiveness and location
of vapor retarders to avoid condensation and subsequent damage
to the structures (ASHRAE Handbook of Fundamentals). Since
foam sheathings are non-structural, they must be installed over
adequately braced framing in accordance with local building codes.
Intertek CCRR 1021;
CA BEARHFTI Lic. No. TB 1334;
Florida Product Approval – No. FL14164;
CCMC 12722-L;
MN Dept. of Energy – Chapter 7640;
FM Approvals - see RoofNav Roof System Listings;
Miami-Dade County, FL - NOA No. 12-0629.04;
UL LLC
®
See Classication Certicate A183.
General
These instructions are intended for use by any individual, whether
an experienced installer or homeowner. They are general guidelines
and do not cover all aspects of insulation installation and use. As
the installer, you have sole responsibility for proper installation of all
materials. You are responsible for adhering to label instructions and
using proper safety precautions during installation.
The installation information provided describes some
common applications and represents current industry
practice. This information is intended to be used as a guide.
For information regarding other applications and more
detailed product information go to
www.kingspaninsulation.us.
Alternate installation details may be used if approved in
writing by Kingspan Insulation LLC prior to installation.
Personal Protective Equipment
For safe handling, it is recommended that you use OSHA-approved
safety glasses, work gloves, and a NIOSH or MSHA approved
disposable dust respirator. There is no requirement for re-entry or
occupancy times.
Required Tools
For all Kingspan GreenGuard
®
XPS Insulation Board installations,
one or more of the following tools will be required:
1. Tape measure
2. Straightedge
3. Utility knife
4. Nail gun
5. Caulk gun
6. Cordless drill
7. Hammer
8. Saw

Summary of content (6 pages)