Dimension Guide

PRODUCT MODEL NUMBERS
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Because Whirlpool Corporation includes a continuous commitment to improve our
products, we reserve the right to change materials and specifications without notice.
Ref. W10888962
05/23/2016
Page 1 of 1
KOCE507E
27" (68.6 cm) and 30" (76.2 cm) Electric Built-In
Microwave/Oven Combination
PRODUCT DIMENSIONS
27" and 30" (68.6 cm and 76.2 cm) Ovens
ELECTRICAL CONNECTION
To properly install your oven, you must determine the type of electrical
connection you will be using and follow the instructions provided for it
here.
Oven must be connected to the proper electrical voltage, amperage,
and frequency as specified on the model/serial/rating plate. See the
following illustration.
A. Model/serial/rating plate
27" (68.6 cm) models
A. 42
9
/
16
" (108.0 cm) overall height
B. 25
7
/
16
" (64.6 cm) recessed
width
C. 41" (104.1 cm) recessed height
D. 23
1
/
4
" (59.1 cm) max. recessed
depth
E. 27" (68.6 cm) overall width
F. 48" (121.9 cm) flexible conduit
length measured from the
conduit clamp located at the
rear of the oven. Do not remove
the conduit clamp.
Models rated from 7.3 to 9.6 kW at 240 volts (5.4 to 7.4 kW at 208
volts) require a separate 40-amp circuit. Models rated at 4.8 kW and
below at 240 volts (3.6 kW and below at 208 volts) require a separate
30-amp circuit.
A circuit breaker is recommended.
Connect directly to the fused disconnect (or circuit breaker box)
through flexible, armored or nonmetallic sheathed, copper cable (with
grounding wire).
Flexible conduit from the oven should be connected directly to the
junction box.
Do not cut the conduit. The length of conduit provided is for
serviceability of the oven.
A UL Listed or CSA Approved conduit connector must be provided.
If the house has aluminum wiring, follow the procedure below:
1. Connect a section of solid copper wire to the ends of the flexible
conduit leads.
2. Connect the aluminum wiring to the added section of copper wire
using special connectors and/or tools designed and UL Listed for
joining copper to aluminum.
Follow the electrical connector manufacturer’s recommended
procedure. Aluminum/copper connection must conform with local
codes and industry accepted wiring practices.
For power requirements, refer to the following table.
Model Voltage Amperage
(L1)*
Amperage
(L2)*
Rating (W)
KOCE507E/
KOCE500E
120/240 32 30 8000
KOCE507E/
KOCE500E
120/208 30 28 6600
* Amperage values noted above are for information purposes only: The
units are rated in watts.
30" (76.2 cm) models
A. 42
9
/
16
" (108.0 cm) overall height
B. 28
7
/
16
" (72.2 cm) recessed
width
C. 41" (104.1 cm) recessed height
D. 23
1
/
4
" (59.1 cm) max. recessed
depth
E. 30" (76.2 cm) overall width
F. 48" (121.9 cm) flexible conduit
length measured from the
conduit clamp located at the
rear of the oven. Do not remove
the conduit clamp.
A
B
A
C
D
E
F

Summary of content (2 pages)