Owners Manual

9
The front face of the cleats and platform will be visible and should
be treated as a finished surface.
Front View Side View
27" (68.6 cm) models
A. 5/8" (1.6 cm) top cleat*
B. 27
1
/
4
" (69.2 cm) minimum
width of flush inset cutout
C. 25
7
/
8
" (65.7 cm) minimum
width of opening
D. 43
1
/
2
" (109.5 cm) minimum
height of flush inset cutout
E. 42
1
/
2
" (107.9 cm)
recommended cutout height
F. 11/16" (1.7 cm) side cleat*
G. 1/2" x 2" (1.3 cm x 5.1 cm)
spacer the entire depth of the
cutout*
H. Recommended junction box
location
I. 4
5
/
8
" 19
1
/
4
" (11.7 - 48.9 cm)
bottom of cutout to floor
J. 25" (63.5 cm) minimum depth
of cutout
30" (76.2 cm) models
A. 5/8" (1.6 cm) top cleat*
B. 30
1
/
4
" (76.8 cm) minimum
width of flush inset cutout
C. 28
7
/
8
" (73.3 cm) minimum
width of opening
D. 43
1
/
8
" (109.5 cm) minimum
height of flush inset cutout
E. 42
1
/
2
" (107.9 cm)
recommended cutout height
F. 11/16" (1.7 cm) side cleat*
G. 1/2" x 2" (1.3 cm x 5.1 cm)
spacer the entire depth of the
cutout*
H. Recommended junction box
location
I. 4
5
/
8
" 19
1
/
4
" (11.7 - 48.9 cm)
bottom of cutout to floor
J. 25" (63.5 cm) minimum depth
of cutout
* Cleats and spacers must be recessed 1
3
/
8
" (3.5 cm) from the
front of the cabinet.
Top View
27" (68.6 cm) models
A. 1/2" x 2" (1.3 cm x 5.1 cm)
spacer the entire depth of the
cutout*
B. 25" (63.5 cm) depth of cutout
C. 1
1
/
2
" (3.5 cm) recess from front
of cabinet
D. 11/16" (1.7 cm) side cleat*
30" (76.2 cm) models
A. 1/2" x 2" (1.3 cm x 5.1 cm)
spacer the entire depth of the
cutout*
B. 25" (63.5 cm) depth of cutout
C. 1
1
/
2
" (3.5 cm) recess from front
of cabinet
D. 11/16" (1.7 cm) side cleat*
* Cleats and spacers must be recessed 1
3
/
8
" (3.5 cm) from the
front of the cabinet.
Electrical Requirements
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path and the wire gauge are in accordance with local
codes.
Check with a qualified electrical installer if you are not sure the
oven is properly grounded.
This oven must be connected to a grounded metal, permanent
wiring system.
Be sure that the electrical connection and wire size are adequate
and in conformance with the National Electrical Code, ANSI/NFPA
70-latest edition or CSA Standards C22.1-94, Canadian Electrical
Code, Part 1 and C22.2 No. O-M91-latest edition, and all local
codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575