Dimension Guide

PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
Compactor
KUCS03FT KTTS505E
Electrical: This compactor is for use on a single
phase, 115-volt, 60 Hz, AC only, 15- or 20-amp
fused and properly grounded circuit and is
equipped with a grounding plug as shown below. It
is recommended that a separate circuit serving only
this appliance be provided.
CUSTOM PANELS
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10242569B
2/15
34
1
8"
(86.7 cm)
24"
(61 cm)
15"
(38.1 cm)
CABINET OPENING DIMENSIONS CLEARANCE DIMENSIONS
A
B
1. Leave 6" (15.2 cm) of clearance
space to the right side of the
compactor in order to remove the
compactor bags.
2. Leave 23" (58.4 cm) of clearance
in front of the compactor in order
to fully open or remove the
compactor drawer.
Without Trim Kit
18" min.
(45.7 cm)
24" min.
(61 cm)
A
15 min.
(38.7 cm)
34 " min.
(87 cm)
3" min.
(7.6 cm)
"
18" min.
(45.7 cm)
24" min.
(61 cm)
A
15 min.
(38.7 cm)
34 " min.
(87 cm)
3" min.
(7.6 cm)
"
1. Grounded electrical outlet
must be a minimum of 3"
(7.6 cm) away from
surrounding cabinets or
nearby walls as shown. It
can be placed either to
the left or the right side of
the product.
29
(
74.6 cm
)
15 "
(
38.1 cm
)
³⁄₈"
Panel should be a minimum of
½" (13 mm) thick.

Summary of content (1 pages)