Use And Care Manual

9
Connect Vent System
1. Install vent system.
2. Push duct over the exhaust outlet. Seal all connections with
vent clamps.
3. Use caulk to seal all openings.
Non-Vented (Recirculating) Installation
1. Attach the air deflector to the upper horizontal support using
4 mounting screws.
2. Measure the length of 6" (15.2 cm) duct needed to connect
the transition to the deflector.
NOTE: Vent should fit up inside the deflector 1" (2.5 cm)
minimum.
3. Install vent between the transition and the deflector.
NOTE: To make vent installation easier, temporarily remove
the deflector from the chimney support bracket, and then
replace after vent section is in place.
4. Seal all connections with vent clamps.
A. Deflector
B. Mounting screws
B
B
A
7. Install the 4 lower vertical supports with 16 - 4.2x8 mm
screws. Make sure all screws are tightly fastened.
A. 4 - Lower vertical supports
B. 16 - 4.2x8 mm screws
B
A
6. Attach the range hood assembly to the lower vertical
supports with 2 leveling screws and 2 nuts.
A. 2 - Leveling screws
B. Lower vertical support
C.
Place leveling screws
through the structure
D. Nut
A
B
C
D
5. Using 2 or more people, lift the range hood assembly under
the structure.
A. Lower vertical supports
B. Range hood assembly
A
B