Owners Manual
Table Of Contents
- Vent System Safety
- Installation Requirements
- Installation Instructions INTERIOR-MOUNTED VENT MOTOR
- INSTALLATION INSTRUCTIONS EXTERIOR-MOUNTED VENT MOTOR
- VENT SYSTEM USE
- VENT SYSTEM CARE
- Troubleshooting
- Wiring Diagrams
- Assistance or service
- SÉCURITÉ DU SYSTÈME DE VENTILATION
- EXIGENCES D'INSTALLATION
- INSTRUCTIONS D’INSTALLATION VENTILATEUR MONTÉ À L’INTÉRIEUR
- INSTRUCTIONS D’INSTALLATION VENTILATEUR MONTÉ À L’EXTÉRIEUR
- Méthodes d’évacuation
- Installation du conduit d’évacuation
- Achever l’installation
- Installation du ventilateur en ligne (type externe) du système d’extraction par le bas
- Raccordements électriques du système de ventilation en ligne
- Raccordement de l’alimentation électrique au système d’extraction par le bas
- Contrôle du fonctionnement
- UTILISATION DU SYSTÈME D’EXTRACTION
- ENTRETIEN DU SYSTÈME D’ÉVACUATION
- Dépannage
- SCHÉMA DE CÂBLAGE
- ASSISTANCE OU SERVICE
22
6. Use UL listed wire connectors and connect the blue wires
(F) together.
7. Use UL listed wire connectors and connect the gray wires
(G) together.
8. Connect the green (or yellow/green) ground wire to the
green/yellow ground wire (H) in the terminal box using UL
listed wire connectors.
9. Reinstall the in-line blower terminal box cover and screw.
10. Reinstall the front cover of the in-line blower housing and
secure it with ten mounting screws.
Electrical Connection Inside Downdraft Vent Between
In-Line Blower System and Downdraft Vent
NOTE: Discard the 6-wire connector assembly supplied with the
in-line blower motor system.
1. With the downdraft vent mounted, locate the bottom wiring
cable (ve wires) inside the downdraft vent terminal box.
2. Connect the wires from the bottom wiring cable (ve wires)
inside the downdraft vent terminal box to the wires from
the in-line blower wiring conduit inside the downdraft vent
terminal box.
3. Connect the same color wires to each other (black to black,
white to white, etc.) using UL listed wire connectors.
NOTE: Connect the green (or green/yellow) ground wire from
the wiring conduit to the green (or bare) ground wire from the
home power supply using UL listed wire connectors. (See
the “Make Electrical Power Supply Connections to
Downdraft Vent” section.)
4. Go to “Make Electrical Power Supply Connection
to Downdraft Vent” section.
Make Electrical Power Supply
Connection to Downdraft Vent
1. Disconnect power.
2. Locate the downdraft vent terminal box.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
A
B
C
D
E
F
G
H
I
A. UL listed or CSA approved
1/2" (1.3 cm) wiring
conduit
B. UL listed wire connectors
C. Black wires
D. White wires
E. Red wires
F. Blue wires
G. Gray wires
H. Green (or green/yellow)
wire
I. Bottom wiring cable
(ve wires)
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
A. Terminal box
A
B
C
D
E
F
A. Green or green and yellow
ground wires
B. White wires
C. UL listed wire connectors
D. Black wires
E. UL listed or CSA approved
conduit connector
F. Downdraft vent wiring