Product Brochure

Voltage
Range
12 - 48 VOLTS AC
(Low) NCVT-2 only
50 - 1000 VOLTS AC
(Standard)
Audible
low-pitched pulsing beeping sound high-pitched continuous beeping sound
Visual
blue LED turns off and
red LED blinks (approximately
2x per second).
green LED turns off and
red LED illuminates continuously.
3TMV
Cat. No. Voltage Range Frequency Range Pollution Degree Batteries Overall Length Width Height Weight Weight w/Batteries
NCVT-3 12 - 1000V AC 50 - 500 Hz 2 2 x AAA 5-53/64" (148.0 mm) 23/32"(18.3 mm) 5-7/8" (149.2 mm) 1.2 oz. (34 g) 2.5 oz. (71 g)
24V
120V
~
2"
(
~
51
mm)
NCVT-3
NCVT-1
NCVT-2
Cat. No. Voltage Range Frequency Range Pollution Degree Batteries Overall Length Width Height Weight Weight w/Batteries
NCVT-1 50 - 1000V AC 50 - 500 Hz 2 2 x AAA 5-1/2" (139.7 mm) 23/32"(18.3 mm) 1" (25.4 mm) 0.8 oz (23 g) 1.6 oz. (45 g)
NCVT-2 12 - 1000V AC 50 - 500 Hz 2 2 x AAA 5-1/2" (139.7 mm) 23/32"(18.3 mm) 1" (25.4 mm) 0.8 oz (23 g) 1.6 oz. (45 g)
Non-Contact Voltage Tester with Flashlight (NCVT-3)
Non-contact detection of voltage (12 - 1000V AC) in cables, cords, circuit breakers,
light fixtures, switches, outlets and wires as well as voltage in security, entertainment,
communications, environmental control and irrigation systems
The visual indicator of the presence of voltage is an LED bar graph - the higher the
voltage sensed, or the closer to the voltage source, the more LEDs light up
Bright flashlight illuminates work area and may be used independent of NCVT
Auto Power-Off feature conserves and extends battery life
Lightweight, compact tool with pocket clip provides easy storage and quick access
IP67: Dustproof and waterproof
6.6 ft. (2 m) drop protection
CAT IV 1000V safety rating
Does NOT detect DC voltage
Non-Contact Voltage Testers (NCVT-1/NCVT-2)
Non-contact detection of standard voltage (48-1000V AC) in cables, cords,
circuit breakers, lighting fixtures, switches, outlets, and wires
High intensity, bright green LED indicates the tester is operational and aids in
illuminating the workspace
Microprocessor controlled low-battery indicator
Digitally controlled ON/OFF power button
Auto Power-Off feature conserves and extends battery life
Lightweight, durable polycarbonate plastic resin construction with a
convenient pocket-clip
9.8 ft. (3 m) drop protection
CAT IV 1000V safety rating provides expanded operation and protection
Does NOT detect DC voltage
Additional Features for Dual Range NCVT-2
Automatically detects and indicates low voltage (12 - 48 Volts AC) and
standard voltage (48 - 1000 Volts AC), allowing broad application
Non-contact detection of low-voltage in security, entertainment,
communications, environmental control, and irrigation systems
Electrical Testers
See page 310 for additional information on warnings.
www.kleintools.com
216