GENERAL SPECIFICATIONS
Dimensions: 6.8" L x 3.6" W x 1.85" D
(173 mm L x 91 mm W x 47 mm D)
Weight:
18 oz. (510 g) with batteries
Operating Temperature: 32°F to 122°F (0°C to 50°C)
Storage Temperature: -22°F to 140°F (-30°C to 60°C)
Humidity: 10% to 90%, non-condensing
Altitude: 10,000 ft (3,048 m) operating
Voltage:
RJ Jack: 66V DC or 55V AC
F-Connector: 50V DC or AC
Voltage Warning: At maximum Safety Extra Low Voltage
limits (60V peak AC or DC). Measurement continues while
warning is displayed.
Battery Life: 6 x AA alkaline batteries
Standby: 10 years
Active: 20 hours (average)
Enclosure: High-strength PC/ABS plastic with UL94, V0
rating with boot.
Drop Protection: 4 ft. (1.2 m)
Languages: English, Spanish, French
Measurement Method: Time Domain Reflectometry (TDR)
Cable Measurements:
Cable Testing and ID: up to 1,000 ft (305 m)
Split Pair Detection: 3 ft. (1 m) to 1,000 ft. (305 m)
Length: 0 to 1,500 ft (457 m), ± 5% and 1 ft. (0.3 m)
Remote support:
Supports 8 Test-n-Map
TM
ID remotes (RJ11/12/45)
Supports 20 RJ-45 and 20 F-Connector ID only remotes
Power over Ethernet:
Tests for IEEE 802.3af and IEEE 802.3at (PoE Plus) compliant PoE
Tests for classes and loads cable up to 25.5 watts
(at class 4) Identifies Mode A or B (pairs with PoE)
Active Ethernet: Indicates advertised speeds of
10/100/1000base-t half or full duplex. Can link to network
at 10/100base-t
Tone Generation:
Tone frequencies: 730 Hz and 1440 Hz
Test Memory Storage:
Stores up to 256 cable or network
tests with user defined names.
Safety Compliance: CE
Disposal Compliance: WEEE
WARNINGS
To ensure safe operation and service of the tester, follow
instructions. Failure to observe these warnings can result in
severe injury or death.
The VDV Commander is designed for use on cabling systems
with
Safety Extra Low Voltage (SELV)
or without voltage.
Do NOT use the VDV Commander when the Voltage! icon
is present. The Voltage! icon turns on when the voltage
exceeds Safety Extra Low Voltage (SELV) rating of 60 Volts
peak AC or DC. Operating the VDV Commander when a
voltage source exceeds 60 Volts peak AC or DC may pose
a safety hazard for the user.
SYMBOLS:
WARNING: Potential for personal injury.
Caution: Potential for damage or destruction to equipment.
Always wear approved eye protection.
Do NOT use on energized circuits.
Conformité Européenne. Conforms with
European Economic Area directives.
This symbol indicates that equipment and its accessories
shall be subject to a separate collection and correct disposal.