Installation Manual

Use the up and down arrow buttons
to
navigate through the settings.
Use the left and right arrow buttons to select setting.
Use the up and down arrow buttons
to change
the selected setting.
Press the "Enter" button
to accept your changes.
Press the left arrow to unselect a setting.
Changing a Setting
RJ45 VoP : VoP
Set the VoP to be used to measure RJ45 cable.
Coaxial VoP : VoP
Set the VoP to be used to measure coaxial cable.
TIA568A/TIA568B: Set the RJ45 wiring configuration to
TIA568A or TIA568B wiring standard.
Pair/Pin: Set the RJ45 wiremap to measure by pair or pin.
Meters/Feet :
Set the length measurement to be
displayed in Meters or Feet.
Pair/Pin can be changed to test the RJ45 from Wire Order to
Pair Order.
Power Off Timeout:
Set the desired automatic
timeout from 00.5 - 99.9 minutes.
LCD Dimmer Timeout:
Set the desired automatic
timeout from 00.5 - 99.9 minutes.
Language: Set the desired language from English (default) to
Spanish or French.
Tone Generator Timeout: Set the desired automatic timeout
00.5 - 99.9 minutes.
PoE Test: Turn the PoE test On or Off. Turning the PoE off
will allow the VDV Commander to detect a network without
running a PoE test.
Press the “Calibrate” function button to calibrate the VDV
Commander. This will calibrate the VDV Commander at 0 ft.
No cables should be connected to the VDV Commander when
performing a calibration.
Press the "Save"
function button to save your options.
Note: If only temporary change is desired, do not press the
save button. If the save button is not pressed, the previous
settings will be restored once the unit is powered off.
To restore factory default values, press the "Defaults"
function button.
To view saved files, press the Files function button.
ENGLISH