Temperature Limiting Adjustment
CAUTION: Risk of personal injury. The water temperature
should never be set above 120°F (49°C).
Turn the valve stem clockwise to the full open position. Allow the
water to run for several minutes.
Using a thermometer, check the water temperature.
Turn off the water.
Minor Temperature Adjustment
Using a hex wrench, turn the setscrew clockwise to lower the
temperature and counterclockwise to raise the temperature.
Recheck the water temperature.
Major Temperature Adjustment
Remove the O-ring and collar from the valve stem.
Slowly turn the valve stem until the water temperature is 120°F
(49°C) or less.
Leave the water running at the desired maximum temperature
and reinstall the collar with the setscrew positioned against the
tab.
Turn off the water.
Reinstall the O-ring.
Collar
O-Ring
Setscrew
Minor Adjustment
Valve Stem
Major Adjustment
Tab
1110626-2-J 14 Kohler Co.