CFI230G Indigo Quadrant Enclosure with integrated Mira Magna Shower System (646) Slide Rail Fixed Head 4 3 2 1 4 3 2 1 Kohler Daryl Limited Alfred Road, Wallasey, Wirral, CH44 7HY England Tel 44 (0)151 606 5000 Fax 44 (0)151 638 0303 www.daryl-showers.co.uk E-mail Daryl@daryl-showers.co.
CUSTOMER SERVICE Kohler Daryl and Kohler Mira Daryl Showering have more than 38 years experience of manufacturing and designing shower enclosures of exceptional quality. For over 80 years, Mira Showers have had the same reputation for shower systems. Your new showering product has been created by these two specialist organisations from within the same leading world-wide bathroom company Kohler. They are both bound by the same values of delivering beauty, quality, innovation, reliability and service.
Indigo Quadrant Enclosure The Daryl Care Programme Keeping your enclosure beautiful throughout its lifetime is easy with products from the Daryl care programme Using state of the art bespoke machinery combined with the latest technology, all Daryl doors and panels are coated with a glass protector in highly controlled factory conditions. The protector acts as an invisible barrier on the glass to prevent build up of limescale, soap scum, stains and dirt.
CLEANING COMPONENTS Standard Top Caps Lintel The unit should be cleaned regularly. LH Cap x2 Use a non abrasive cleaner (ideally with a pH value of 4 to 8) applied with a soft cloth. Parking Block Side Panel Under no circumstances should scourers or powerful detegents be used as these can damage the metallic surface of the frame and also tarnish the glass coating.
COMPONENTS TROUBLESHOOTING The information below gives details on what you can do as a user should you encounter difficulties whilst operating the shower. Water Delivery Top Caps LH If there is a problem with the shower control some of the push buttons will flash very fast.
ENCLOSURE INSTALLATION Non Water Delivery Side only Loosely fit wall channel into glass panel jamb Carefully lift the assembly onto the tray. The end of the glass panel fits into slot ‘A’ on the tray. The wall channel end sits on the flat section of the tray ‘B’ A B Handset Adjustment B To adjust the height of the handset press the release button ‘A’ and slide the clamp bracket assembly up or down to the desired position.
Spray Settings The handset has three different spray actions: Start, Soothe and Massage and an Eco setting. To adjust the spray setting turn the spray plate as follows: Check the wall channel is vertical and mark through the 3 holes ‘A’ Drill 3 x 6mm holes Fit the splash guard to the bottom of the panel. Note: lip faces to the outside of Enclosure and cutout is towards the wall end of the glass 1. Start - Water flows from the outer set of holes.
Ensure glass panel is vertical Drill 4 x 3mm holes through jamb into wall channel OPERATION Check glass is vertical. If not remove screws, re-drill and re-fit as required. Low, Medium or High Flow Button - Buttons glow BLUE when pressed Re-fit rubber strip over screws Temperature Control Knob Fit 4 x B screws Warm Up/Off Button - glows BLUE when powered B STEP 9 STEP 11 STEP 10 Carefully remove the Water Delivery System from the Water Delivery Wall Jamb. Slacken screws ‘A’.
The lock mode may be activated when the unit is OFF in which case the unit cannot be switched ON unless the mode is cancelled as above. Removing power from the unit also cancels the mode Carefully lift the assembly onto the tray. The end of the glass panel fits into slot ‘A’ on the tray. The wall channel end sits on the flat section of the tray ‘B’ Adjust wall jamb until glass is parallel to the edge of the tray ‘A’ and vertical at ‘B’. 4.
Check the wall channel and jamb is vertical. Loosen screws ‘A’ to adjust from side to side. Re-tighten screws The edge of the glass should fit against the end of the slot in the tray ‘B’. To adjust the glass loosen the 4 screws ‘C’ and move the panel until it is the correct postion. Re-tighten screws COMMISSIONING 1. General 1.1. Turn on the water supply to the Digital Mixer. 1.2. Check for leaks over the complete system. 1.3. Turn on the electrical supply to the Digital Mixer.
Fit top cap - Water delivery side Fit top cap - Non Water delivery side C C Loosely fit the parking block into the wall mount ‘A’. Lift the lintel onto the glass. The panel clamps fit over the top edge of the glass and should be equally spaced on each panel C A Note: The lintel is supplied as a RH unit. For LH versions loosen the panel clamps and turn them through 180o STEP 46 STEP 47 Ensure glass panels are parallel to each other STEP 22 Check top rail is level.
Fixed Head Water Delivery Only Remove the lintel from glass and remove the parking block 1. Match parking block to mark on wall 2. Spot drill hole positions Carefully lift the Water Delivery System column and place the bottom into the jamb assembly 3. Drill holes with 6mm drill Be very careful not to scratch or damage the tray Support the weight of the column. Plug the electrical cable into the connector on the cable from the Water Delivery System Caution 4. Plug holes 5.
Fit the Suppression Ferrite close to the Water Delivery connector Slider Rail Water Delivery Only (See Step 42 for the Fixed Head Water Delivery) Note: The Suppression Ferrite is packed with the Digital Mixer Place the cable in the suppression ferrite.
Loosen the screw fixing the bottom roller to the glass with a 3mm allen key Locate other side of glass door panel between the roller and plastic glass guide Fit door retainers to both top roller brackets. Caps will ‘click’ and lock in place Lift bottom roller up and tighten the fixing screw with a 3mm allen key.