Dimensions Guide

C
L of Outlet
24-7/16" (620 mm)
2-1/8"
(54 mm)
10" (254 mm) or
12" (305 mm)
10-1/2"
(267 mm)
13-1/8" (333 mm)
6" (152 mm)
9-3/8"
(238 mm)
Front of Bowl
For Back-to-Back Toilet Installations
Use a 45° double
wye fitting.
Do not use a
double sanitary tee.
Finished Wall
Finished Floor
2"
(51 mm)
5-7/8"
(149 mm)
15-1/8"
(384 mm)
1-1/2"
Spud
1-1/4"
(32 mm)
14-7/16"
(367 mm)
Notes
Technical Information
Install this product according to the installation
instructions.
All product dimensions are nominal.
Flushometer, Floor-mountToilet type:
For back-to-back toilet installations: Use only a
45° double wye fitting.
FloorWaste Outlet:
Elongated frontBowl shape:
Requires flushometer valve to match desired
water consumption 1.28 gpf (4.8 lpf) or 1.6 gpf
(6 lpf).
Flushometer valve siphonFlush type:
1-1/2", Inlet, TopSpud size:
1-7/8" (48 mm)Trap passageway:
ADA compliant when installed to the specific
requirements of these regulations.
Water Consumption
1.28 gpf (4.8 lpf) or 1.6 gpf (6 lpf)Full:
Plumbing codes may require elongated toilets
and elongated, open-front seats in public
bathrooms.
10" x 7" (254 mm x 178 mm)Water surface size:
4-3/8" (111 mm)Rim to water surface:
Accessibility standards may require controls to
be located on the open side of the toilet.
12Rough-in:
Fixture Supply Requirements
35 psi (241.3 kPa)Min static pressure:
80 psi (551.6 kPa)Max static pressure:
25 psi (172.4 kPa)Min flowing pressure:
25 gpm (94.6 lpm)Min flow rate:
1-800-4KOHLER (1-800-456-4537)
Kohler Co. reserves the right to make revisions without notice to product specifications.
For the most current Specification Sheet, go to www.kohler.com.
9-28-2018 15:21
Primary
Elongated Floor Mount, Flushometer Bowl
K-96064