Specification

Optional Accessories
88526 HiFlow Rite-Temp
®
thin wall installation kit CP Other ____
1073881 HiFlow Rite-Temp thick wall installation kit NA
Installation Notes
Install the valve trim according to the installation guide.
Install the Rite-Temp valve according to the installation guide.
NOTICE: Risk of product damage. Long screws, for
installing trim, can damage the K-2971-KS valve. Consult the
trim installation guide to verify if the thin wall installation kit
(88526) is needed.
Avoid cross-flow conditions. Do not install a shut-off device on
either valve outlet.
Cap the shower outlet if the deck-mounted spout, diverter, or
handshower is connected to the spout outlet.
Install a 7 (17.8 cm) to 18 (45.7 cm) straight pipe or straight
tube with single bath elbow between the valve and the
wall-mount spout.
4"(10.2 cm)
6"(15.2 cm)
4-1/2"
(11.4 cm)
6-1/2"
(16.5 cm)
1/2" NPT
1/2" Hot
1/2" Cold
10"(25.4 cm)
6-1/2"
(16.5 cm) D.
2-3/4" (7 cm) Thin Wall
3-1/2" (8.9 cm) Thick Wall
For slip-fit spout, 5-8" OD tube
must extend 5"(12.7 cm) beyond
finished wall.
For 1/2" NPT threaded spout,pipe
must extend 5"(12.7 cm)
beyond finishedwall.
72"(182.9 cm)-
78"(198.1 cm)
to floor (Typical)
48"(121.9 cm)
to floor
(Shower Only)
Product Diagram
KELSTON
®
RITE-TEMP
®
KELSTON
®
RITE-TEMP
®
BATH AND SHOWER VALVE TRIM
Page2of2
1105000-4-
C