88526 Thin wall installation kit for K-2971-KS HiFlow Rite-Temp valve CP Other ____
1073881 Deep roughing-in kit for K-304 and K-2971 Rite-Temp valve NA
1016453 Diverter button kit for K-305-K and K-305-KS Rite-Temp valves CP Other ____
1092535 Deep roughing-in kit for K-305 Rite-Temp valve CP Other ____
1156950 Deep roughing-in kit for K-11748 Rite-Temp valve CP Other ____
K-45129 Shower arm and flange CP Other ____
K-5327 Diverter bath spout CP Other ____
K-5328 Non-diverter bath spout CP Other ____
Installation Notes
Install the valve trim according to the installation guide.
Install the Rite-Temp valve according to the installation guide.
CAUTION: Risk of product damage. Long
screws, for installing trim, can damage the
K-2971-KS valve. Consult the trim installation
guide to verify if the thin wall installation kit
(88526) is needed.
Avoid cross-flow conditions. Do not install a shut-off device on
either valve outlet.
Cap the shower outlet if the deck-mounted spout, diverter, or
handshower is connected to the spout outlet.
Install a 7 (178 mm) to 18 (457 mm) straight pipe or straight
tube with single bath elbow between the valve and the
wall-mount spout.
4" (102 mm)
6-3/4" (171 mm)
4-1/8"
(105 mm)
6" (152 mm) Thick Wall
6-3/4" (171 mm) Thin Wall
1/2" NPT
1/2" Hot
1/2" Cold
Ø 6-7/16"
(164 mm)
2-3/4" (70 mm) Thin Wall
3-1/2" (89 mm) Thick Wall
If over 3-1/2" (89 mm) and
up to 4-1/4" (108 mm),
use deep roughing-in kit.
For slip-fit spout, 5/8" OD
tube must extend 5-9/16" (141 mm)
beyond finished wall.
For 1/2" NPT threaded spout,
pipe must extend 5-9/16" (141 mm)
beyond finished wall.
72" (1829 mm) -
78" (1981 mm)
to floor (Typical)
48" (1219 mm)
to floor
(Shower Only)
10" (254 mm)
to Spout
(Bath Only)
Ø 1-5/8" (41 mm)
Max Hole in the Wall
Supply tube must
be centered in the
hole.
Product Diagram
REFINIATM RITE-TEMP
®
REFINIATM RITE-TEMP
®
BATH AND SHOWER VALVE TRIM
Page2of2
1157045-4-