Use and Care Manual

13
OPERATION
Final Check List before Operation
1. Have all packing materials and tape been removed from the interior and exterior of the
ice maker?
2. Did you clean the ice storage bin?
3. Have the installation instructions been followed, including connecting the machine to
water, drain and electricity?
4. Has the machine been leveled?
5. Is the ice maker in a site where the ambient temperature is between 10º C (50º F) and
38ºC (100ºF) and the water temperature within C (41º F) and 32º C (90º F) all year
round?
6. Has the water supply pressure been checked to ensure a minimum of 20 psig with a
static pressure not to exceed 80 psig?
7. Is there a clearance of at least 4 in. at the rear and top, 0.6 in. at the sides for proper air
circulation?
8. Has the power supply voltage been checked or tested against the nameplate rating?
9. Has the machine been properly grounded and connected into a three prong AC outlet?
10. Is the ice maker plugged in?
11. Did you turn on the main water supply and the tap?
12. Did you check for leaks at all water supply and drainpipe connections?
13. Has the machine been connected to a floor drain? If you do not have a floor drain a
condensation pump will be required.