Use and Care Manual

19
5. Remove the slideway from the water sump.
6. Find the sprinkler and raise it. Disconnect it from the water tube which is
connected at the back of the sprinkler arm.
7. A de-scaling solution can be prepared in a plastic
basin with Nu-Calgon Nickel-Safe Ice Machine
Cleaner. Mix 4 ounces of the ice machine cleaner
per gallon of warm water. Remove the sprinkler arm
from the interior, unscrew the sprinkler nuts,
separate the centrifuge parts from the nuts and pull
the end plug out. Thoroughly clean the parts by
soaking them in the basin filled with the de-scaling
solution until they are free of any deposit; use a soft
Sprinkler arm
Slideway
Sprinkler arm
Water tube
Water sump
Sprinkler
Sprinkler nut
Centrifuge part
End plug
Sprinkler arm