Use and Care Manual

Operation panel
ATIMER CLEAN button
Quickly press this button once, to enter the Timer
setting program; And press this button for more than 5
seconds, to enter the Cleanin g program.
BON/OFFbutton
When the unit is off, press this button to turn on the
unit; And during the Self-cleaning program, or normal
ice-making state, pre ss this button to turn off the unit
at once; And also if the unit is set with the Timer,
press this button to cancel the Timer setting.
When the unit is making the ice cube, press t
his
button for more than 5 seconds, the unit will switch to
ice harvest process by force.
CLCD display window
1.Environmental temperature display and ice - makin
g
time countdown display.Display ice-making time
countdown with M as the unit display,and display
environmen tal tempe rature with F as the unit display.
2Making ice and deice symbol display,the machine is
making ice when the symbol rotate,and the machine
is deice whe n the symb o
l flas h. .
3Automatic self-clea
ning symbol display
4On/off symbol display
5Error code displayE1 means the environmen tal temperature sensor is dam aged.E2 means
ice making anomaly or the refrig erant leaked
6Water flow in and water shortag e display, the arrow flashing indicates that the machine is in
the water, the whole symbol is bright to indicate that the machine is short of water.
7Ice full alarm,the machine will making ice again when you
take out the ic e.
8Setting display.Display timing switch machine with the H as unit disp lay;Display ice making
time setting with M as un it display.
D&E+-button
Use to adjust the ice-maki
ng process duration period leng th, the default setting is zero, 1
minute adding or decreasing per each press ing of “+” or “-” button.
Also to ad just the delay time of the timer, the default setting is zero, 1 hour adding or
decreasing pe r each pressing of +” or “-” button.
ON/OFF
TIMER
CLEAN
+
-
2)
7