User's Manual

Configuring the FC-8 Wi-Fi - RS-232 Bridge
11
Parameter Possible Values Notes
Wireless LAN WEP Key1 WEP64 – no more than 10
characters (5 bytes) allowed
(hex 0-9 A-F)
WEP128 – no more than 26
characters (13 bytes)allowed
(hex 0-9 A-F)
Wireless LAN WEP Key2 Same as WEP Key1
Wireless LAN WEP Key3 Same as WEP Key1
Wireless LAN WEP Key4 Same as WEP Key1
Pre-shared Key Passphrase WPA – ASCII string must be
between 8-63 alphameric
characters
SerialNet Serial Parameters <b, d, p, s, f >
5, 8, N, 1, 0 (Default)
Where:
b = baud [1–9 or h] (see Table 4)
d = data bits [7 or 8]
p = parity [N, E, O]
s = stop bits [1]
f = flow [0, 1]
Default IP 192.168.3.2
Set to 0.0.0.0 to receive IP
address from a DHCP server
Factory default address
[Submit] Enters the changes made in the
configuration table
[Refresh] Redisplays values of the configuration
screen
Table 4: Baud Rate Settings
Baud Code Baud Rate Baud Code Baud Rate
1 600 6 19200
2 1200 7 38400
3 2400 8 57600
4 4800 9 115200
5 9600 h 230400
2. Change the parameters as needed to attach the FC-8 to the new network and
press Submit.
Important: When changing the IP address, input the same new address into
both the Active IP Address field and in Default IP field.
Note: It may take a few minutes for the update to complete.
Warning: You must enter the correct network parameters. If the parameters
are incorrect, the network will not recognize the unit and you will not be able to
access the device until it is reconfigured using a special program
1
, which can
be downloaded from the Kramer Web site.
1 The FC-8 must be connected to a PC over the serial port while running the program