Owner manual

MS424 7
The rating of the rear panel fuse is as follows
230V 115V
T100mA T200mA Both are slow blow type
Please note:
If the fuse requires changing at any time please ensure the correct type is
fitted. An incorrect fuse could cause damage to the unit and may
constitute a fire hazard.
The detachable IEC mains lead connections to the appliance are coloured in
accordance with the following code:
Green-and-Yellow Earth
Blue Neutral
Brown Live
WARNING: THIS APPLIANCE MUST BE EARTHED
Please note:
A protective earth connection, made by way of the earth conductor in the
power cord, is essential for safe operation.
3.5 EXTERNAL CONNECTIONS
The Inputs on the Model MS424 are female XLR type connectors. These are
wired as follows -
XLR-F Pin 1 * Screen
Pin 2 Hot (+ve)
Pin 3 Cold (-ve)
* Pin 1 is ground lifted by a 100R resistor to Audio ground and by a 47nF