User guide

17
9.0 SPECIFICATIONS
Dimensions: The unit has a T-shaped configuration.
Max. Unit width: 4.5”
Max. Unit height: 5.75
Max. Unit depth: 3.5
Note: See page 2 for dimensional images
Weight: 2 LBS.
AC Input: 90 – 240 VAC 50/60/400 Hz, 500 mA
AC Inlet: Standard IEC-320 (60320) receptacle. 3 wire grounded.
Mates with USA and international IEC line cords. Internal
AC fuse protection.
AC Line Cord: Provided: 6 ft. 3 Wire with IEC-320 plug one end and
standard NEMA 15-5, 125V plug on the other end. Change
line cord or use adapter plug for 230V input.
Ambient Operating temp: 0 to 40°C (32 – 104°F)
Storage Temp: -40 to 80°C (-40 – 125°F)
Fan Cooled
DC OUTPUT
10 Amp max pulse for low batteries (below 18V), then approx. 3 ~ 5 Amps
electronic current and voltage limiting.
Charge regulation within AC line limits and low to full charge load ± 1%
RMS Ripple 0.25 %, except during pulsing. Pulsing 10A 1ms, 2 pulses / sec.
Internal AC and DC fuse protection.