User's Manual

4 / 18 www.lansitec.com
ADR
0: OFF
1: ON
ADR (Adaptive Date Rate) status. The default value is
OFF.
MODE
0x01~0x07
Current working scheme which should be one of
SMODE.
0x1: AU920
0x2: CLAA
0x3: CN470
0x4: AS923
0x5: EU433
0x6: EU868
0x7: US915
SMODE field
Name
Value
Description
SMODE
0x01: AU920
0x02: CLAA
0x04: CN470
0x08: AS923
0x10: EU433
0x20: EU868
0x40: US915
Data scheme supported by Device.
This field is preserved by Lansitec and will be
configured before shipping. For European
market, the default value is EU868, for China
market, the default value is CN470, for
Southeast Asia market, the default value is
AS923, for America market, the default value is
US915. Currently only support one kind of
mode.
POWER field
Name
Value
Description
POWER
0~31
Configured transmit power. The default
value depends on the Device working mode, it’s
always the biggest one of the allowed
power. For example, if the mode is EU868, the
default value of POWER should be 14dbm.
(Unit: dBm)
Reserved
0x0
Reserved for future use. If MODE is CLAA, it
indicates the frequency sweep mode of
the Device:
1: A mode
2: B mode
3: C mode
4: D mode
5: E mode
6: All frequency sweep
CFG field
C256U-PQ User Manual