Category Description
LEDs TX/RX activity per serial
Link/Activity per Ethernet port
Power/System OK
Isolation 8 KV direct contact, 15 KV air discharge, ESD protection on all serial ports (IEC 1000-4-2,
IEC 61000-4-2)
2 K VAC / 2.8K VDC galvanic isolation between power input port to Ethernet ports (except
chassis ground)
2 K VAC / 2.8K VDC galvanic isolation between power input port to serial ports
Transient Voltage protection and ESD with max non-repetitive surge current 800 A (8/20
us) (IEC 61000-4-2)
2 K VAC / 2.8K VDC galvanic isolation between Ethernet ports (except chassis ground)
2 K VAC / 2.8K VDC galvanic isolation between Ethernet ports to serial ports
40 A (5/50 ns) EFT protection (IEC 61000-4-4), 12 A (8/20 us) lightning protection (IEC
61000-4-5) on all Ethernet ports
Agency Approvals UL, CSA, FCC, CE, TUV, CTick, VCCI, FM Class 1, Div. 2