Data Sheet

U.I. Lapp
GmbH
DATA SHEET
ETHERLINE
®
P FLEX Cat. 5e 2x2x26/7 AWG
DB2170284
valid from: 25.11.2013
Originator:
RAWE/
PDC
approved: HAPF/PDC
Document: DB2170284 page 2 of 2
All rights reserved acc. to DIN ISO 16016.
PD 0019/2.2_11.10DE
Transmission properties
Transmission properties acc. to IEC 61156-6: abstract of the minimum requirements shown in the table:
f
[MHz]
Attenuation
[dB/100m]
NEXT [dB]
PS NEXT
[dB]
EL FEXT
[dB/100m]
PS EL FEXT
[dB/100m]
RL
1
3,2 65,3 62,3 - - -
4
6,1 56,3 53,3 52,0 49,0 -
10
9,6 50,3 47,3 44,0 41,0 -
16
12,1 47,2 44,2 39,9 36,9 -
31.
25
17,2 42,9 39,9 34,1 31,1 23,3
62.
5
24,9 38,4 35,4 28,1 25,1 20,7
100
32,2
35,3
32,3
24,0
21,0
19,0
Mechanical and thermal properties
Minimum bending radius
moved: 15
x cable Ø
fixed installation: 8 x cable Ø
Permissible temperature range
moved (V
DE):
-
5
˚ C up to +
5
0
˚ C
fixed installation (VDE): -30˚ C up to +80˚ C
moved (UL): -5˚ C up to +80˚ C
fixed installation (UL): -30˚ C up to +80˚ C
Halogen free
acc. to
VDE 0472
-
815
Flame retardant
acc. to IEC 60332
-
1
-
2
General requirement
s
Dangerous and forbidden substances acc. to RoHS directive (20
11/6
5/E
U
)