Installation Guide

Table Of Contents
13
leakSMART
®
PRO
Device Reset Procedures
To reset the valve controller, rapidly press the center button 5 times. The Blue LED light will
begin to flash indicating it is reset and ready to join the system.
Note 1: Sometimes the device may require that it be power cycled in advance. This is done
by removing the AC adapter cord connector and also removing a battery if any are installed.
Then power back up and procced by pressing the center button 5 times rapidly.
Note 2: If resetting the valve while connected to an existing leakSmart
®
system where the
valve is visible in the App, the valve will drop off, in being removed from the system.
To pair the valve, Put the smart system hub in pairing mode, press the center button once
on the valve, check app for the valve to show up. Note: Once joined, all lights will go dark.
Drive Motor and electrical contact
housing assembly, operating on
6v DC Max.
Electrical contacts must engage
spring tab contacts, inside valve
controller housing.
1. Valve Controller
1. Battery pack
Holds 4x AA
batteries,
included.
(Note: Never
replace battery
block with a
9v battery)
1. Brass Ball Valve
Basic Valve and Controller Diagram
Controller
Remove
control top for
installation.
Note: controller
can be placed
either side of the
valve body.
Sector gear can
be accessed for
manual operation.
Flow direction identified
by arrow on valve body.
Controller