Product Literature

GUIDE SPECIFICATIONS
Project Name Project No. Date
Project Location 16140-12 Wiring Devices
copper-clad conductors; SafeLock
®
Protection performs an automatic test every
three seconds to insure that ground fault protection is active; auto-ground clip;
indicator light; [light almond] [ivory] [white] [gray] [red] [orange] color. RoHS
Compliant.
Specifier Note: Retain one or more colors and delete the others in brackets after Part No. and
from description.
15A Hospital Grade Self-Test Combination Tamper-Resistant Night Light/GFCI
Duplex Receptacles: Part No. 1597HGNTLTR[I][W][--][RED]; rated 15 amps,
125 volts; nylon face, body, and test/reset buttons; thermoplastic tamper-
resistant shutter; terminals accept #14 - #10 AWG solid or stranded copper or
copper-clad conductors; SafeLock
®
Protection performs an automatic test every
three seconds to insure that ground fault protection is active; auto-ground clip;
indicator light; Lexan
®
nightlight lens; [ivory] [white] [brown] [red] color. RoHS
Compliant.
Specifier Note: Retain one or more colors and delete the others in brackets after Part No. and
from description.
20A Hospital Grade Self-Test Combination Tamper-Resistant Night Light/GFCI
Duplex Receptacles: Part No. 2097HGNTLTR[LA][I][W][GRY][RED]; rated
20 amps, 125 volts; nylon face, body, and test/reset buttons; thermoplastic
tamper-resistant shutter; terminals accept #14 - #10 AWG solid or stranded
copper or copper-clad conductors; SafeLock
®
Protection performs an automatic
test every three seconds to insure that ground fault protection is active; auto-
ground clip; indicator light; Lexan
®
nightlight lens; [light almond] [ivory] [white]
[gray] [red] color. RoHS Compliant.
Specifier Note: Retain one or more colors and delete the others in brackets after Part No. and
from description.
15A Hospital Grade Self-Test Audible Alarm Tamper-Resistant GFCI Duplex
Receptacles: Part No. 1597HGTRA[LA][--][GRY]; rated 15 amps, 125 volts; nylon
face, body, and test/reset buttons; thermoplastic tamper-resistant shutter;
terminals accept #14 - #10 AWG solid or stranded copper or copper-clad
conductors; SafeLock
®
Protection performs an automatic test every three
seconds to insure that ground fault protection is active; auto-ground clip; audible
alarm; [light almond] [brown] [gray] color. RoHS Compliant.
Specifier Note: Retain one or more colors and delete the others in brackets after Part No. and
from description.
20A Hospital Grade Self-Test Audible Alarm Tamper-Resistant GFCI Duplex
Receptacles: Part No. 2097HGTRA[LA][I][W][RED]; rated 20 amps, 125 volts;
nylon face, body, and test/reset buttons; thermoplastic tamper-resistant shutter;
terminals accept #14 - #10 AWG solid or stranded copper or copper-clad
conductors; SafeLock
®
Protection performs an automatic test every three
seconds to insure that ground fault protection is active; auto-ground clip; audible
alarm; [light almond] [ivory] [white] [red] color. RoHS Compliant.
Specifier Note: Retain one or more colors and delete the others in brackets after Part No. and
from description.
20A NAFTA-Compliant Hospital Grade Self-Test Tamper-Resistant GFCI Duplex
Receptacles: Part No. 2097HGTRNA[LA][I][W][RED]; rated 20 amps, 125 volts;
nylon face, body, and test/reset buttons; thermoplastic tamper-resistant shutter;