Operation Manual

Rugby 410/420 DG 15Setup
H.I. (Height of
Instrument)
The H.I. function is used to prevent elevation changes caused by move-
ment of the tripod.
When the H.I. Alert function is activated, the self-leveling accuracy
remains the same, but the self-leveling range of the Rugby is reduced.
Movement of the Rugby beyond its self-leveling range will cause an “alert
condition”. The Rugby will stop rotating and the following screen will
appear on the display:
Stop thealert condition by pressing the Star or Power button and reset
the function.
Check carefully the setup and elevation of the unit to determine what
has caused the alert condition. Adjust as required to the correct eleva-
tion.
The H.I. function can be turned on or off in the first setup screen.
When the H.I. function is turned on, the letters “HI” will appear in the
bottom, right part of the display.
The H.I. function becomes active 30 seconds after the unit has
completely leveled and the head starts rotating.
Automatic and
Manual Mode
The Rugby will always turn on in automatic mode and will continuously
self-level to maintain grade accuracy.
)
In manual mode the self-leveling function is turned off.
The display screen will show the following:
The X-axis slope can be changed using the X/Y and arrow buttons, but
the amount of change is not shown in the display.
The H.I. function can be made to turn on automatically at
power-up. This can be enabled in the second setup screen.