Operation Manual

Rugby 410/420 DG Accessories22
6.3 Remote Control
The Rugby LR Remote Control (765668) is a full functioning, two-
way remote control.
The LCD display and the grade and star buttons on the remote are the
same as on the Rugby.
The Power button turns on only the remote. When pressed it
will communicate with the Rugby to receive current information.
Once communication is established, the remote can be used to
change grade and setup parameters on the laser.
If the remote is not within range or otherwise loses communication, the
lost communication screen will be displayed.
It is important, to achieve specified distances, that the remote be used
within the “line of sight” of the Rugby.
Press and hold the power button for 1.5 seconds to turn the remote off.
The Standby button will cause the Rugby to go into standby
mode for up to 16 hours. After this time the Rugby will shut off
and can only be turned on again at the laser.
When in standby mode the display will show only a sleeping Rugby.
Pressing any button (except power) while the unit is in standby mode will
cause the laser to return to normal operation.
Automatic Shut Off - To conserve battery power, the remote will auto-
matically shut off after two minutes of non-use.