Rugby 410/420 DG 25Troubleshooting
7 Troubleshooting
7.1 Display Screen Explanations
Leica Start-up Screen
Can be programmed to display customer’s name and
address.
Battery Status Screen
Displays on power-up
Displays also when batteries are empty.
Automatic Mode
Main Display Screen
Unit automatically self-levels.
Manual Mode
Unit will not self-level
Grade can be changed with the grade/arrow buttons.
Manual Mode with Grade
Unit will self-level to grades input, then lock in
manual mode.
Grade can be changed with the grade/arrow buttons.
Stand-by Mode
Controlled by the stand-by button on the remote.
Press the power button on the Rugby to turn off.
H.I. Alert Warning
Unit has moved and elevation may have changed.
Press Power or Star to reset H.I. function.
Check unit’s elevation and adjust if required.
Servo Limit Warning
Unit is not level
Check setup and circular level vial.
Tilt Warning
Unit is tilted more than 30°.
Temperature Warning
Unit is too hot or cold to operate properly.
Shade unit if too hot.
Warm unit before continuing if too cold.