Datasheet

Dimensions AP(R)-B420L (unit : mm, 1mm = 0.0394 inch)
Connections
Wires up to 2 mm
Female connector provided (spring terminal blocks)
User-friendly spring-cage connection for no-tool direct
conductor connection
Mechanical characteristics
General tolerance ± 1 mm
Primary aperture 18.5 mm
Panel mounting 2 holes 4.0 mm
Distance between holes 40.0 mm
For panel mounting, replace M4 screws by new one (not
supplied) with appropriate length to panel´s thickness.
Front View
Bottom View
Left View
Axis of aperture
Plug-in connector included : XW4B-03C1-H1 (OMRON)
(distance between screws)
55
40
3
3
.
5
0
20
Range Selection Switch
67
6
9
2
1
37
D
I
N
s
i
z
e
3
5
.
5
0
1
4
.
8
0
25
16.40
4
.
7
0
1
8
.
5
0
18.50
Ip
Is
OUT
+24VDC
GND
Ip
Is
OUT
+24VDC
GND
Load
(+)
2(-)
(-)
1(+)3none
Output
Range Switch
4-20mA
(Controller,
Meter, etc,)
AP/APR
Connector
Front
071022/6 www.lem.com