Electric Heater User Manual

17
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
MODEL NO.
CI1500DVF Series
MANUFACTURED AT: Burlington, WA
FOR USE WITH NATURAL GAS. EQUIPE POUR GAZ NATUREL
ALTITUDE
MIN. GAS SUPPLY PRESS (“WC)
PRESS MIN. D’ALIMENTATION (“CE)
MANIFOLD PRESSURE (“WC)
PRESSION CE TUBULURE (“CE)
MANUFACTURER’S RECOMMENDED ORIFICE SIZE
DIMENSION DE L’INJECTEUR RECOMMANDE PAR
MANUFACTURIER (DMS)
MAX INPUT (BTUH)
ENTRÉE MAX (BTUH)
MIN INPUT (BTUH)
ENTRÉE MIN (BTUH)
0-4500 FT (0-1370 M)
4.5”
3.5”
#37
28,000
17,500
ELECTRICAL RATING/EXIGENCES ELECTRIQUES:
OPTIONAL FAN/SOUFFLEUR OPTIONAL
-UNIT/APPAREIL: MILLIVOLT
1 ph
60 HZ
120 VOLTS
LESS THAN 5 AMPS
MINIMUM SIDEWALLS
FLOOR
2”
0”
CLEARANCES TO CEILING OR ALCOVE HEIGHT
BACK/CORNER 45°
62”
4”
COMBUSTIBLE
MATERIAL
VENT SURFACES: TOP
SIDES
BOTTOM
3”
1”
1”
ALCOVE MAXIMUM DEPTH 48”
DEGAGEMENT MUR ADJACENTS
PLANCHER
50.8mm
0mm
MINIMUM DE PLAFOND OU HAUTEUR D'ALCÔVE
EN ARRIÈRE ET COIN 45 ANGLE
1574.8mm
101.6mm
MATERIAUX
COMBUSTIBLES
SURFACES D’AERATION: DESSUS
COTES
BAS
76.2mm
25.4mm
25.4mm
PROFONDEUR D'ALCÔVE MAXIMALE 1219.2mm
DIRECT VENT GAS STOVE / APPAREIL A GAZ AVEC EVACUATION DIRECTE
VENTED GAS STOVE HEATER – NOT FOR USE WITH SOLID FUEL.
FOYER DE CHAUFFAGE AU GAZ A EVACUATION - NE DOIT PAS ETRE UTILISE AVEC UN
COMBUSTIBLE SOLIDE.
FOR USE WITH GLASS DOOR CERTIFIED WITH THE APPLIANCE ONLY.
N’UTILISER SEULEMENT QUE LA PORTE DE VERRE CERTIFIE AVEC L’APPAREIL.
“CAUTION:
Do not operate the appliance with glass removed, cracked or broken.
Replacement of panel should be done by a licensed or qualified service person.”
“This appliance is equipped at the factory for use with natural gas only. Units using
propane must be field converted using the LP conversion kit, P/N LB-102158A”
FINAL INSPECTION BY:
ANSI Z21.88-2002
CSA 2.33-2002
CAN/CGA-2.17-M91
VENTED GAS STOVE HEATERS
FOYER DE CHAUFFAGE AU GAZ A EVACUATION P/N 9-1452A
SERIAL NUMBER/NOMBRE DE SERIE
XXXXX XXXXX
IIIIIIIIIIIIIIIIIIII
XXXXXXXXXXXXXXXX
P/N 9-1452A
MODEL NO.
CI2500DVF Series
MANUFACTURED AT: Burlington, WA
FOR USE WITH NATURAL GAS. EQUIPE POUR GAZ NATUREL
ALTITUDE
MIN. GAS SUPPLY PRESS (“WC)
PRESS MIN. D’ALIMENTATION (“CE)
MANIFOLD PRESSURE (“WC)
PRESSION CE TUBULURE (“CE)
MANUFACTURER’S RECOMMENDED ORIFICE SIZE
DIMENSION DE L’INJECTEUR RECOMMANDE PAR
MANUFACTURIER (DMS)
MAX INPUT (BTUH)
ENTRÉE MAX (BTUH)
MIN INPUT (BTUH)
ENTRÉE MIN (BTUH)
0-4500 FT (0-1370 M)
4.5”
3.5”
.121
38,500
25,500
ELECTRICAL RATING/EXIGENCES ELECTRIQUES:
OPTIONAL FAN/SOUFFLEUR OPTIONAL
-UNIT/APPAREIL: MILLIVOLT
1 ph
60 HZ
120 VOLTS
LESS THAN 5 AMPS
MINIMUM SIDEWALLS
FLOOR
2”
0”
CLEARANCES TO CEILING OR ALCOVE HEIGHT
BACK/CORNER 45°
62”
4”
COMBUSTIBLE
MATERIAL
VENT SURFACES: TOP
SIDES
BOTTOM
3”
1”
1”
ALCOVE MAXIMUM DEPTH 48”
DEGAGEMENT MUR ADJACENTS
PLANCHER
50.8mm
0mm
MINIMUM DE PLAFOND OU HAUTEUR D'ALCÔVE
EN ARRIÈRE ET COIN 45 ANGLE
1574.8mm
101.6mm
MATERIAUX
COMBUSTIBLES
SURFACES D’AERATION: DESSUS
COTES
BAS
76.2mm
25.4mm
25.4mm
PROFONDEUR D'ALCÔVE MAXIMALE 1219.2mm
DIRECT VENT GAS STOVE / APPAREIL A GAZ AVEC EVACUATION DIRECTE
VENTED GAS STOVE HEATER – NOT FOR USE WITH SOLID FUEL.
FOYER DE CHAUFFAGE AU GAZ A EVACUATION - NE DOIT PAS ETRE UTILISE AVEC UN
COMBUSTIBLE SOLIDE.
FOR USE WITH GLASS DOOR CERTIFIED WITH THE APPLIANCE ONLY.
N’UTILISER SEULEMENT QUE LA PORTE DE VERRE CERTIFIE AVEC L’APPAREIL.
“CAUTION:
Do not operate the appliance with glass removed, cracked or broken.
Replacement of panel should be done by a licensed or qualified service person.” .”
“This appliance is equipped at the factory for use with natural gas only. Units using
propane must be field converted using the LP conversion kit, P/N LB-102158B”
FINAL INSPECTION BY:
ANSI Z21.88-2002
CSA 2.33-2002
CAN/CGA-2.17-M91
VENTED GAS STOVE HEATERS
FOYER DE CHAUFFAGE AU GAZ A EVACUATION P/N 9-1452F
SERIAL NUMBER/NOMBRE DE SERIE
XXXXX XXXXX
IIIIIIIIIIIIIIIIIIII
XXXXXXXXXXXXXXXX
P/N 9-1452F