Installation and Operation Manual

7
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Figure 4
Figure 3
Planning Installation
Safety and General
Installation
Operation
Maintenance
Troubleshooting
Parts / Accessories
Footnotes:
1- These dimensions to the stove body are for reference only. Actual distances should be measured from the stove’s flue collar.
2- Minimum noncombustible hearth pad dimensions.
3- Clearances to connector pipe shall be measured from the flue collar of the stove.
4- Not applicable to alcove installations.
5- In corner applications, when installed at minimum back wall clearances, the required floor protection is dimensioned off the back plane of the stove, therefore the floor
protection required off the back corners (at a 45 degree angle) only needs to extend to the wall. This situation will only occur in CANADA installations.
6- Reference dimension only, to assist in planning the installation.
7- Measured from front of floor protection to the front of firebox.
8- USA=8” (200mm) from door opening, Canada=8” (200mm) from sides and back of unit.
INSTALLATION CLEARANCES - REFER TO FIGURES 2, 3 AND 4
Planning Installation
USA (inches)
PIPE INSTALLATION A (3) B (1) C (3) D (1) E (8) F (1,4) G(3,4) H (2)
I
(6) J (2) K (7) L (5) M T (6) U
Single Wall Residential-Vertical Vent 16 12-3/8 22
12-1/2
8 5-11/16 16 38-5/8 51 33 16 0 90 58-7/8 N/A
Single Wall Residential-With Elbow 19 15-3/8 23
13
-1/2 8 5-11/16 16 38-5/8 54 33 16 0 90 58-7/8 19
Double Wall Residential or Mobile Home-Vertical Vent 10 6-3/8 20
10-1/2
8 4-11/16 15 38-5/8 45 33 16 0 90 57-1/2 N/A
Double Wall Residential or Mobile Home-With Elbow 10 6-3/8 21
11-1/2
8 4-11/16 15 38-5/8 45 33 16 0 90 57-1/2 10
Double Wall Alcove-Vertical Vent 13 9-3/8 22-1/2 13 8 N/A N/A 38-5/8 48 33 16 0 90 N/A N/A
CANADA (millimeters)
PIPE INSTALLATION A (3) B (1) C (3) D (1) E (8) F (1,4) G(3,4) H (2) I (6) J (2) K (7) L (5) M T (6) U
Single Wall Residential-Vertical Vent 406 314 559
318
200 145 406 1235 1346 1045 450 200 2286 1495 N/A
Single Wall Residential-With Elbow 483 391 584
343
200 145 406 1235 1422 1045 450 200 2286 1495 483
Double Wall Residential or Mobile Home-Vertical Vent 254 160 508
267
200 119 381 1193 1193 1045 450 200 2286 1461 N/A
Double Wall Residential or Mobile Home-With Elbow 254 160 533
293
200 119 381 1193 1193 1045 450 200 2286 1461 254
Double Wall Alcove-Vertical Vent 330 238 572 331 200 N/A N/A 1235 1270 1045 450 200 2286 N/A N/A
Stove
Stove
Stove
Alcove
Floor
Protection
Floor
Protection
Floor
Protection
Combustible Wall
Combustible Wall
Combustible
Wall
Alcove Depth
48" (1219mm) MAX.
E
USA
E
USA
K
K
J
D
C
B
A
L
H
I
T
F
F
G
G
M
I
U
Corner Installation
Alcove or Parallel Installation
Alcove or Parallel Installation
Elbow
Elbow
Figure 2
Top View
Side View
Top View
E
Canada
† See note 8