Indoor Fireplace User Manual

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
24
Scoop
Scoop Securing Screws
Fire Box Top
Lintel Securing Screw
Hole in Cabinet Top
Figure 37
Blocked Flue Safety Limit Location,
Inside View of Firebox,
Top/Right Side Intersection
Detail A
Detail C
Fire Box Top
Limit
Limit/Bracket
Securing Screws
Lintel Securing-Screw
Hole in Cabinet Top
View Without Scoop
Figure 38
Step 13. HOOD INSTALLATION
All of these appliances must have a hood installed prior to operating on the side with a glass
enclosure panel.
On louvered face units, slide the hood into the slots on the lower edge of the cabinet top (see
Figure 38).
FINISHING REQUIREMENTS
Wall Details
Complete finished interior wall. To install the appliance facing flush with the finished wall,
position framework to accommodate the thickness of the finished wall (see Figure 38).
Combustible Wall
Framing
Combustible Finished
Wall Materials
This area must remain clear
of combustible materials.
1" (25 mm)
Minimum
Top of Appliance
Top of Door Frame
Louvers
Louver Face Models
Hood must be installed as shown.
Noncombustible Finished
Wall Materials
Combustible Wall
Framing Spacer
3" (76 mm)
Minimum
4 - Remove the safety switch bracket securing
screws (2), and pull the switch/bracket
assembly, with low voltage wires attached,
through the side panel slot into the firebox.
See Figure 37, Detail C.
5 - Replace the switch.
6 - Reinstall the switch/bracket assembly.
7 - Reinstall the scoop and lintel.
8 - Reinstall the glass enclosure panel.
9 - Raise the bottom control compartment
access panel.
10 - The appliance should then relight and
remain lit. If this does not occur, check
unit for a blocked flue condition.
Detail B
Wire
Termianls
Back Of
Limit
Switch
Cabinet
Corner
Door
Frame
Header